Automatic Fire Suppression Systems for Telecommunications Centre

Product Details
Customization: Available
Agent: FM200
Type: Automatic
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
886813.09 USD
Management System Certification
ISO9001:2015
Find Similar Products

Basic Info.

Model NO.
EFS-04
Object
Class B Fires
Size
6L
Certification
CE
Portable Extinguisher
Portable
Effective Range
4.5m
Retirement Life
5 Years
Dry Powder Type
Superfine Powder
Power Source
Pressure Fire Extinguisher
Fire Agent
FM200
Application
Computer Suites and Data Centres
Capacity
2L, 6L,9L,12L
Product Name
FM200 Automatic Fire Suppression Systems
Key Words
FM200 Automatic Fire Suppression Systems
Panting Color
Red
Raw Material of Cylinder
Steel or Stainless Steel
Activated Temperature
140 Degrees~160 Degrees
Transport Package
Professional Export Carton
Specification
450x290x200mm
Trademark
PRI-SAFETU
Origin
Hangzhou, China
HS Code
84241000
Production Capacity
5000 Units/Year

Product Description

Automatic Fire Suppression Systems for Telecommunications Centre
Automatic Fire Suppression Systems for Telecommunications Centre


1. Product Information of Automatic Fire Suppression Systems for Telecommunications Centre:
1) Key Advantages:
  • Applied to the relatively closed space effectively;
  • Heated start, no electricity;
  • Simple installation and maintenance;
  • Full automatic;
  • Special for Vehicle Engine Room.
2) FM200 Benefits: 
  • Colourless, odourless, non-contaminating gaseous fire protection
  • Designed to protect critical assets and processes without damaging them
  • Safe to use in occupied areas
  • Proven in thousands of successful installations around the world
  • Hygood quality & technical/service support
3) Technical paramters sheet: 
    Automatic Fire Suppression Systems for Telecommunications Centre
    Brand Name Pri-Safety
    Capacity 1L,2L, 3L, 4L, 6L, 9L, 12L
    Fire Agent FM200
    Working Pressure 14Bar
    Testing Pressure 27Bar
    Cylinder Material SS304 or St12 red painting
    Certificate CE0036
    Activiation Temperature 140ºC or 160ºC

    4). Working Principle

    Step1:Detection Tube ruptures to hole when temperature reach 140ºC or 160ºC,and Spraying through the hole.(Or pushing the manual valve at the end of detection tube,pressure releasing from the tube end and spraying.)
    Step2:The resulting drop in pressure causes the head valve to be activated.
    Step3:Valve was opened and agent was discharged through the discharge tubing to the nozzles.
    Step4:Agent covering the area and suppressing the fire quickly and thoroughly.
    This system is totally automatic and is totally independent of electricity.


    Kindly check this testing video from our customer.Https://youtu.Be/Q9amEXisOCk

    2. Product Image.
    1) Stainless Steel Type and Carbon Steel Type.
    Automatic Fire Suppression Systems for Telecommunications Centre
    Automatic Fire Suppression Systems for Telecommunications Centre



    3. Application of Automatic Fire Suppression Systems for Telecommunications Centre:
    Φ Computer suites and data centres
    Φ Gas turbine enclosures
    Φ Offshore oil/gas exploration & production facilities
    Φ Telecommunications centres
    Φ Power generation
    Φ Marine
    Φ Museums, archives and data storage


    Automatic Fire Suppression Systems for Telecommunications Centre


    4.Packing and shipping.
    Automatic Fire Suppression Systems for Telecommunications Centre

    5.Exhibition show.
    Automatic Fire Suppression Systems for Telecommunications Centre

    6.FAQ.
    1)Automatic Fire Suppression Systems for Telecommunications Centre used for what's kind of fire?
    FM200 for Vehicle & Electrical Equipments.
    ---1L/2L used for normal car engine bay;
    --- 6L used for bus or truck engine bay.

    2).May I get a sample before placing an order?
    ---Yes, no problem.

    3).Are your company PRI-SAFETY a manufacturer or trading company?
    ---Manufacturer.

    4).Can you print our logo on products?
    ---Yes, no problem.We also support OEM.

    5).How long does it take to delivery?
    ---In 30-45 days after receipt of 30% deposit.

    7).What's your MOQ?
    ---Fire extinguisher is class2.2 Dangerous Goods, it should be loaded with full container.
    But if you have another goods shipping together or you need empty type, our MOQ is 100 sets.






     

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now