Restaurant Kitchen Automatic Kitchen Fire Risk Management System

Product Details
Customization: Available
Agent of Kitchen Fire Systems: Wet Chemical
Cylinder Material: SS304
Still deciding? Get samples of US$ 870/Set
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
886813.09 USD
Management System Certification
ISO9001:2015
  • Restaurant Kitchen Automatic Kitchen Fire Risk Management System
  • Restaurant Kitchen Automatic Kitchen Fire Risk Management System
  • Restaurant Kitchen Automatic Kitchen Fire Risk Management System
  • Restaurant Kitchen Automatic Kitchen Fire Risk Management System
  • Restaurant Kitchen Automatic Kitchen Fire Risk Management System
  • Restaurant Kitchen Automatic Kitchen Fire Risk Management System
Find Similar Products

Basic Info.

Model NO.
KFS-02
Certificate
CE Marked
Working Pressure(Bar)
14bar
Test Pressure(Bar)
27bar
Discharge Pipe
Dia. 16mm SS304
Type
Indirect
Activation Temperature Detection Tubes)
170
Support
OEM
Transport Package
by High Quality Export Packaging
Specification
12L
Trademark
PRI-SAFETY
Origin
China
HS Code
842410
Production Capacity
10000sets/Month

Product Description

Wet Chemical Automatic Fire Suppresion Systems For Commerical Kitchen
Restaurant Kitchen Automatic Kitchen Fire Risk Management System
 
1. Working Principle
PRI-SAFETY kitchen fire suppression systems have been specifically designed to protect home/commercial kitchen and put out cooking fires caused by grease orgrease-laden vapors (class F or class K fire) quickly and efficiently.

These self contained pneumatic systems require no external energy or power supply. Upon flame impingement or heat, the pressurised detection tubing will burst and activate the cylinder valve to open and release the extinguishing agent.

PRI-SAFETY kitchen fire suppression systems are specifically designed to extinguish fires fueled by grease and in a kitchen environment. They use wet chemicals in a fine mist to quickly extinguish fires and offer a quicker clean-up than dry chemicals.
Restaurant Kitchen Automatic Kitchen Fire Risk Management System

2.Components of Kitchen Fire Suppression System

1. Detection tube2. Power
3. Fittings
4. Manual
5. Spray Nozzles
6. Mounting Clips
7. Fire alarm
8. Discharging Tube
Restaurant Kitchen Automatic Kitchen Fire Risk Management System
 
3.Advantages
* Simple, high quality and well engineered system. Easy to install.
* Fast, automatic actuation.
* Stainless steel pipework, fittings and nozzles to suit kitchen environments.
* Linear heat and flame detection, allowing for multiple of detection points. Flexible piping requirements.
* Remaining operational during power interruptio
* Quick, easy clean up once appliances have cooled, the agent can be easily wiped away from equipment

4. Product Parameters
Items No. KFS-02 KFS-06 KFS-09 KFS-12 KFS-20 KFS-25
Capacity 2L 6L 9L 12L 20L 25L
Application For 1m Kitchen Hood For 2~3 m Kitchen Hood For 3~4m Kitchen Hood For 4~5m Kitchen Hood For 6~8m Kitchen Hood For 8~10m Kitchen Hood
Out-Dia.(mm) 110 160 180 180 257 257
Cylinder Length(mm) 302 450 485 621 610 775
Volume(L) 3.8 7.8 10.5 16 27 35
Extinguishing Agent Wet chemical Wet chemical Wet chemical Wet chemical Wet chemical Wet chemical
Working Pressure 14bar 14bar 14bar 14bar 14bar 14bar
Test Pressure 27bar 27bar 27bar 27bar 27bar 27bar
Cylinder Material SS304 SS304 SS304 SS304 SS304 SS304
Discharge Pipe φ12mm SS304 φ12mm SS304 φ16mm SS304 φ16mm SS304 φ16mm SS304 φ16mm SS304
Certificate CE marked CE marked CE marked CE marked CE marked CE marked
Activation Temperature Detection Tube 170ºC 170ºC 170ºC 170ºC 170ºC 170ºC

5. Installation
 
Restaurant Kitchen Automatic Kitchen Fire Risk Management System
1. System Tank
2. Automatic Head Valve
3. Bracket
4. Discharge Pipe
5. Nozzles
6. Emergency Manual Button
7. Fire Alam
8. Control Panel
9. Pressure Switch
6. Application
 
 

Restaurant Kitchen Automatic Kitchen Fire Risk Management System
*2L---For 1m Home Kitchen hood
*6L---For 2-3m Kitchen Hood
*9L---For 3-4m Kitchen Hood
*12L---For 4-5m Kitchen Hood
*20L--- For 6-8m Kitchen Hood
*25L--- For 8~10m Kitchen Hood
Bigger capacity could be customized

7. Packing&Shipping

Restaurant Kitchen Automatic Kitchen Fire Risk Management System
 
Restaurant Kitchen Automatic Kitchen Fire Risk Management System

8. About Us
Restaurant Kitchen Automatic Kitchen Fire Risk Management System
 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now