Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory

Product Details
Customization: Available
Capacity: 32L 70L 90L 120L 150L 180L 250L 345L 450L 500L
Name: Total Flooding Novec1230 Fire Suppression System
Still deciding? Get samples of US$ 1000/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
886813.09 USD
Management System Certification
ISO9001:2015
  • Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
  • Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
  • Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
  • Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
  • Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
  • Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
Find Similar Products
  • Overview
  • Product Description
  • Working Principle
  • Product Parameters
  • Application
  • Production Progress
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
GMQ4.2/**N-PRI
Activate Voltage/ Current
DC24 V/1.6A
Max Working Pressure
4.2MPa, 5.6MPa, 8.0MPa
Fire Agent
Novec1230 / Fk-5112
Certificate
CCC, UL
Working Method
Automatic or Manual
Service
Support OEM
Type
Fixed Fire System
Material
Carbon Steel or SUS304
Model
Single Cylinder, Multiple Cylinders
Transport Package
High Quality Pallets
Specification
32L 40L 70L 90L 120L 150L 180L 250L 345L 450L 500L
Trademark
PRI-SAFETY
Origin
China
HS Code
842410
Production Capacity
3000sets/Month

Product Description

Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory

Product Description

 
The Novec1230 / FK-5112 total flooding fire suppression system offers fast and residue-free extinguishment of fires in critical environments. Utilizing a clean agent that evaporates quickly upon discharge, it effectively extinguishes fires without leaving residue, making it ideal for sensitive areas like data centers, control rooms, and museums. This system reacts swiftly to suppress fires, minimizing damage and downtime while ensuring the safety of personnel and assets. Novec1230 is environmentally sustainable with a low global warming potential and zero ozone depletion potential, aligning with strict regulatory standards. Its versatile design allows for easy installation and integration with existing fire detection systems, providing reliable fire protection tailored to specific spatial requirements. With its rapid response and minimal environmental impact, the Novec1230 system stands as a state-of-the-art solution for protecting valuable assets and maintaining operational continuity in critical infrastructures.
Product Advantage

Easy Operate: Convenient and easy to operate

CCC Authentication: Quality assurance,safety genuine

Alarm system: Real-time detection, alert alerts

Automatic: Fire extinguishing automatically to reduce losses

Not conductive: Safety agent to pro-tect the machine

Environmentally: Green is easy to clean, no residue

Innocuity: Safe medicine, no poison harmless

Fast Fire Extinguishing: Fire extinguishing quickly reduces damage
Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
 

Working Principle


At moment, we have two different Activation Modes.
 

I. Pilot Cylinder Activation Mode

The Pilot Cylinder total flooding Novec 1230 fire system operates as follows.

  1.  Fire Suppression Process:

    • Detection and Activation: Upon fire detection, the system initiates the activation sequence.
    • Pilot Cylinder Activation: The pilot cylinder is activated either automatically upon detection or manually triggered. Activation of the pilot cylinder releases the pressurized gas or liquid stored within it.
    • Valve Operation: The release of pressure from the pilot cylinder operates valves within the system.
    • Solenoid Valve Opening: The pilot cylinder's operation triggers the opening of the main solenoid valve or valves that control the flow of Novec 1230 from the storage containers.
    • Agent Discharge: Novec 1230 is discharged through the distribution piping into the protected area. It quickly fills the space as a gas, displacing oxygen and effectively extinguishing the fire by cooling and interrupting the combustion process.
  2. Advantages:

    • Fast Response: The pilot cylinder system offers rapid deployment of Novec 1230 upon activation, ensuring swift suppression of fires.
    • Reliability: It combines automatic detection with a robust mechanical activation mechanism, enhancing system reliability.
    • Effective Coverage: Ensures comprehensive coverage of the protected area due to the controlled release of the fire suppression agent.
    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
     

    II. Solenoid valve Activation Mode


    The solenoid valve total flooding Novec 1230 fire system operates as follows.

    1. Fire Suppression Process:
      • Fire Detection: Upon detection of a fire by the smoke alarm or temperature alarm, a signal is sent to the fire suppression system.
      • Signal Transmission: The signal is relayed to the control system which activates the solenoid valve.
      • Solenoid Valve Actuation: Upon receiving the signal, the solenoid valve opens, allowing Novec 1230 to discharge from the storage container into the protected area through the piping network.
      • Extinguishing Action: Novec 1230 rapidly fills the protected area as a harmless gas, effectively extinguishing or controlling the fire.
    2. Features and Advantages:

      • Fast Fire Suppression: Novec 1230 has a very short atmospheric lifetime, enabling quick suppression of flames at the onset of a fire.
      • Environmental Compatibility: The agent does not deplete the ozone layer and has minimal impact on the environment.
      • Safety: Compared to traditional gas-based systems, Novec 1230 offers enhanced safety for occupants as it poses no harm at design concentrations.
    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
     

    Product Parameters

     
    1. Cylinders Paremeters
    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
    Item Specification
    Capacity
    32L 70L 90L 120L 150L 180L 250L 345L 450L 500L, support OEM capacity
    Material of Cylinder Normal steel or SUS304 stainless steel
    Spray Time ≤10s
    Power DC24V/1.6A
    Max Working Pressure 4.2MPa, 5.6MPa, 8.0MPa. 
    Thread Size ≤70Lcylinder:PZ56/2-8UN.2A
    ≤90L Cylinder: PZ56/3-1/4"-8UN.2A
    ≤150L Cylinder: M64×2/3-1/4"-8UN.2A
    ≥180L Cylinder: M80×2/3-1/4"-8UN.2A


    2. Normal Head Valve Paremeters
    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
     
    Item DN32 DN40 DN50
    Nech Thread PZ56 M64x2 M80x2
    Actuator Thread M18x1.5
    Dip Tube Thread RC 1-1/4" RC 1-1/2" RC 2"
    High Pressure Flexible Hose Thread M48x2 M56x2 M68x2
    Pressure Guage Thread M10x1 M10x1 M10x1
    Working Pressure 4.2MPa
    Testing Pressure 6.3MPa
    Application Cylinder ≤100L 120L  150L 180L  250L

    3. Normal Pneumatic and Soleniod Valve Paremeters
    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
     
     Pneumatic Valve (Normal Type)
    Code NO. PV-PRI
    Thread M16x1.5
    Working Pressure 6.6MPa
    Solenoid Valve (Normal Type)
    Code NO. SV90N-PRI
    Thread M18x1.5
    Power DC 24V
    Drive Force 90N

    4. High Quality Head Valve Paremeters 
    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
     
    Code NO. AV25/4.2-PRI AV50/4.2-PRI
    AV25/5.3-PRI AV50/5.3-PRI
    Size G 1" G 2"
    Nech Thread 2-8UN.2A 3 1/4-8UN.2A
    Actuator Thread G 1" G 2"
    High Pressure
    Flexible Hose Thread
    G 1" G 2"
    Pressure Guage Thread 1/8" NPT 1/8" NPT
    Working Pressure 6.7MPa
    Testing Pressure 10.05MPa
    Application Cylinder <70L 70L 90L 120L 150L 180L

    5. High Quality Pneumatic and Soleniod Valve Paremeters
    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
     
     Pneumatic Valve (High Quality Model)
    Code NO. APV-PRI
    Thread G 1"
    Working Pressure 6.6MPa
    Solenoid Valve (Hight Quality Model)
    Code NO. ASV90N-PRI
    Thread G 1"
    Power DC 24V
    Drive Force 90N


    6. High Quality Pneumatic and Soleniod Valve Paremeters
     
    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
     
     Gas Check Valve
    Code NO. GCV6/6.6-PRI
    Inlet/Outlet M14*1.5
    Open Force 0.2MPa
    Working Pressure 6.6MPa
    Material HPb59-1
    Pressure Switch
    Code NO. PS0.8/5.3-PRI
    Operating Pressure 0.8MPa±0.08MPa
    Thread RC 1/2"
    Material HPb59-1
     7. Normal Pressure Gauge Paremeters
    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
     
    Code NO.  PG/2.5-PRI  PG/4.2-PRI  PG/5.3-PRI  PG/6.6-PRI
    Working Pressure 2.5MPa 4.2MPa 5.3MPa 6.6MPa
    Thread M10x1
    8. High Quality Pressure Gauge Paremeters 
     
    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
     
    Code NO.  PG/2.5-PRI  PG/4.2-PRI  PG/5.3-PRI
    Working Pressure 2.5MPa 4.2MPa 5.3MPa
    Thread 1/8' NPT
    9. Flexible Hose With Elbow Paremeters
     
    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
     
    Flexible Hose With Elbow
    Size DN32 DN40 DN50
    Code NO.   FHE/32-PRI FHE/40-PRI  FHE/50-PRI
    Thread M48x2 M56x2 M68x2
    Material Brass (HPb59-1)
    Length 700mm
    10. Flexible Hose Without Elbow Paremeters
    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
     
    Flexible Hose Without Elbow
    Size DN32 DN40 DN50
    Code NO.   FH/32-PRI FH/40-PRI  FH/50-PRI
    Thread M48x2 M56x2 M68x2
    Material Brass (HPb59-1)
    Length 500mm
    11. Fire Alarm System
    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory

    Application

    I. Single Bottle With Pilot Bottle or With Solenoid Valve 

    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
    II. Multiple Bottle With Pilot Bottle or With Solenoid Valve 
    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory

    III. Multi-Room Distribution System with Pilot Bottle 
    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory
    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory

    Production Progress

    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory

    Packaging & Shipping

    Pri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From FactoryPri-Safety Total Flooding Novec 1230 Fk-5112 Fire Systems From Factory

    ---the end---

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now
    Contact Supplier