4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder

Product Details
Customization: Available
Agent: Clean Agent, Hfc-227ea, Hfc-236fa, Fk-5112
Type: Automatic Total Flooding

360° Virtual Tour

Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
886813.09 USD
Management System Certification
ISO9001:2015
  • 4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
  • 4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
  • 4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
  • 4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
  • 4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
  • 4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
Find Similar Products

Basic Info.

Model NO.
QMP 180/4.2-PRI
Size
70/90/100/120/150/180/250/345/450L
Certification
ISO9001
Portable Extinguisher
Automatic Total Flooding
Effective Range
Automatic Total Flooding
Retirement Life
5 Years
Dry Powder Type
Clean Agent, Hfc-227ea, Hfc-236fa, Fk-5112
Power Source
Pressure Fire Extinguisher
Working Pressure
4.2MPa
Max. Working Pressure
5.3MPa
Filling Pressure
4.2MPa
Temperature Range
0ºC~50ºC
Model
Qmp 180/4.2-Pri
Filling Agent
Hfc-227ea, Fk-5112
Transport Package
Palletized
Specification
70/90/100/120/150/180/250/345/450L
Trademark
PRI-SAFETY
Origin
China
HS Code
842410
Production Capacity
1000set/Month

Product Description

4.2Mpa 180L FM200 HFC-227ea Total Flooding Fire System Extinguisher System
FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
Desciprion:

FM200, also known as HFC-227ea, is a clean gaseous fire suppression agent commonly used in total flooding fire protection systems. The FM200 system is designed to extinguish fires by rapidly reducing the oxygen concentration within a protected space, thereby suppressing the combustion process. This type of fire suppression system is typically employed in areas where water-based systems might be ineffective or where the use of water could cause damage to sensitive equipment or valuable assets.
 
Specifications:
 
No. Specificaitons Technical Parameter
1 Filling Pressure 4.2Mpa 5.6Mpa
2 Spray Time 10s
3 Cylinder Material Stainless Steel SUS304
4 Cylinder Head Size G1" / G2"
5 Filling density ≤950kg/m3 ≤1080kg/m3
6 Max working pressure 5.3Mpa 8.0Mpa
7 Cylinder Capacity 70L, 90L, 120L, 150L, 180L, 250L, 345L
8 Condition of reserving room for container Temperature: -10~50ºC,
Relative humidity: ≤97%
9 Nitrogen Pressure of Driving Device 6.0±1.0Mpa(20ºC)
10 Valve Material Stainless Steel SUS304
11 Power DC24V/1.6A
12 Scale of Protective region for one zone Area:max single-zone is 800m² volume:max single-zone is 3600m³
 
Key Features:

Clean Agent:
FM200 is a clean gaseous agent, meaning it leaves no residue after discharge. This is particularly important in environments with sensitive electronic equipment, data centers, museums, and other areas where the residue from traditional firefighting agents (like water or foam) could cause damage.

Rapid Suppression:
FM200 is designed to rapidly suppress fires by reducing the oxygen concentration in the protected space. This helps to control and extinguish the fire quickly, minimizing damage to property and reducing downtime.

Effective on Class A, B, and C Fires: FM200 is effective on a wide range of fires, including those involving ordinary combustibles (Class A), flammable liquids (Class B), and electrical fires (Class C). It works by interrupting the combustion process without causing harm to electronic equipment.

Low Ozone Depletion Potential (ODP):
FM200 has a low ODP, meaning it has a minimal impact on the ozone layer compared to some other halogenated fire suppression agents.



Short Atmospheric Lifetime:
FM200 has a relatively short atmospheric lifetime, which contributes to its environmental acceptability. It has a Global Warming Potential (GWP) that is much lower than certain other chemical fire suppression agents.

Safe for Occupied Spaces:
FM200 is considered safe for use in occupied spaces when applied in accordance with design and safety standards. It does not produce toxic by-products in the concentrations used for fire suppression.

Colorless and Odorless:
FM200 is colorless and odorless, making it imperceptible to humans during discharge. This is beneficial in situations where occupants need to evacuate or emergency responders need to work without hindrance.

Precision Delivery:
The system is designed for precision delivery of the agent through a network of pipes and strategically placed nozzles. This ensures even distribution and effective coverage of the protected area.

Compatibility with Electronics:
FM200 is non-conductive and safe for use in areas with sensitive electronic equipment. It can be an ideal choice for protecting server rooms, data centers, control rooms, and other spaces with valuable electronic assets.

Compliance with Standards:
FM200 systems are designed and installed in compliance with industry standards and regulations. This includes adherence to guidelines provided by organizations like the National Fire Protection Association (NFPA) and local authorities.


 
Activation Methods:

Solenoid Head Activation Model:
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
A solenoid valve-activated FM200 fire system is a type of fire suppression system that uses a solenoid valve as a key component in the activation process. The solenoid valve is an electromechanical device that controls the flow of the FM200 fire suppression agent from the storage container to the distribution pipes and nozzles in the protected space.


Solenoid Valve: The solenoid valve is an electrically operated valve that controls the release of the FM200 agent. It is typically located on the piping that connects the storage container or cylinders to the distribution network. When an alarm signal is received or manual activation is initiated, the solenoid valve opens to allow the pressurized FM200 to flow into the distribution system.
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder



Pilot Bottle Activation Model:
A pilot bottle-activated FM200 fire system is a type of fire suppression system that relies on a pilot cylinder or bottle to initiate the release of the FM200 extinguishing agent. This system is commonly used in applications where a fast and precise response is required for fire protection. The pilot bottle serves as a smaller, independent container of the extinguishing agent that is connected to the main storage container.

Here's how a pilot bottle-activated FM200 fire system typically works:

Pilot Bottle: The pilot bottle contains a smaller quantity of FM200 and is pressurized. It is connected to a network of pipes that are also connected to the main storage container.

Pilot Line: A pilot valve is associated with the pilot bottle. This valve is designed to open when a specific condition is met, such as an increase in temperature or the activation of a smoke or heat detector. The pilot valve is usually a heat-sensitive device that responds to the elevated temperatures associated with a fire.

Pilot Line: The pilot bottle is connected to a pilot line that runs through the protected area. This line is typically smaller than the main distribution piping and is designed to actuate the main solenoid valve when the pilot valve opens.

Main Solenoid Valve: Similar to solenoid valve-activated systems, a main solenoid valve is used to control the flow of FM200 from the main storage container to the distribution network. When the pilot valve opens due to a fire condition, it triggers the main solenoid valve to open, releasing the FM200 into the protected space.


 
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder

Accessory Parameters:

4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
FM200 Cylinder Specification---4.2MPa:
(Just Listed some bottle specifications for reference)
Item Capacity(L) Inner Dia.(mm) Height(mm) Wall Thickness(mm) Max. Working Pressure
(Bar)
1 32L 300 620 4 4.2
2 90L 350 1125 4.5 4.2
3 120L 350 1430 4.5 4.2
4 180L 400 1635 5.5 4.2
5 250L 500 1500 8 4.2


FM200 Cylinder Specification---5.6MPa:
(Just Listed some bottle specifications for reference)
Item Capacity(L) Inner Dia.(mm) Height(mm) Wall Thickness(mm) Max. Working Pressure
(Bar)
1 40L 300 747 5 5.6
2 90L 350 1125 6 5.6
3 120L 350 1430 6 5.6
4 180L 400 1635 7 5.6
5 250L 500 1500 9 5.6
 
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder

Specifications for Head Valve of FM200 Fire System
(High Level Model)
Code No. AV25/4.2-PRI AV50/4.2-PRI
AV25/5.3-PRI AV50/5.3-PRI
Item G 1" G 2"
Actuator Thread G 1" G 2"
Working Pressure 6.7Mpa 6.7Mpa
Test Pressure 10.05Mpa 10.05Mpa
Applicable Cylinder ≤70L 90L 120L 150L 180L
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder

FM200 Nozzle for Pipework Type---Female:
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
Control Panel Components:
The control panel for an FM200 total flooding system is a critical component that monitors, controls,
and coordinates the various elements of the fire suppression system.

The components are as followings:

4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
 
Applications of the Stainless Steel Cylinder
FM-200 HFC-227ea Total Flooding Fire System:

The Stainless Steel Cylinder FM200 Total Flooding Fire System is designed for fire protection in various applications, especially in environments where the use of water-based systems is not suitable or could cause damage to sensitive equipment. The use of stainless steel cylinders is beneficial in areas where corrosion resistance and durability are essential. Here are some common applications of the Stainless Steel Cylinder FM200 Total Flooding Fire System:

Data Centers and Server Rooms:
Data centers house critical and sensitive electronic equipment, including servers and networking infrastructure. The FM200 system is well-suited for these environments as it provides rapid fire suppression without causing damage to the electronic components.

Telecommunication Facilities:
Facilities with communication equipment, such as telecommunication rooms and facilities housing switching equipment, benefit from the use of FM200 systems. The clean agent extinguishes fires without leaving residue that could harm sensitive telecommunications equipment.

Control Rooms:
Control rooms in various industries, such as manufacturing, energy, and transportation, often contain valuable and critical control systems. The FM200 system can protect these spaces without causing damage to control panels, displays, and other equipment.
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder


Laboratories:
Research laboratories may house valuable and sensitive equipment, chemicals, and experiments. The FM200 system is suitable for protecting these environments without causing collateral damage to the equipment or experiments.

Museums and Archives:
Cultural institutions, museums, and archives may use FM200 systems to protect valuable artifacts, documents, and collections. The clean agent leaves no residue, reducing the risk of damage to delicate items.

Medical Facilities:
Certain medical facilities, such as imaging rooms and facilities with sensitive medical equipment, can benefit from FM200 fire protection. The system is non-corrosive and safe for use in environments with medical equipment.
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder


Industrial Facilities:
Various industrial settings, including manufacturing plants and facilities with machinery, can employ FM200 systems to safeguard equipment and reduce downtime in the event of a fire.

Server Farms and IT Facilities:
Large-scale IT facilities, including server farms and IT infrastructure rooms, can utilize FM200 systems to protect against fires without the need for water-based systems that could damage the equipment.

 
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
Financial Institutions:
Banks, financial data centers, and other financial institutions often rely on FM200 systems to protect critical infrastructure and sensitive financial data.

Power Generation and Distribution Facilities:
Power plants and facilities involved in the generation and distribution of electricity may use FM200 systems to protect control rooms, switchgear rooms, and other critical areas.

 
Our Workshop:

4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder
About PRI-SAFETY:

PRI-SAFETY was established in 2004, is professional manufacturer of FM200 HFC227EA Fire Protection System,
Automatic Fire Suppression System (For Kitchen. For Vehicle, For Electrical Devices),
CO2 Total Flooding Fire System,
Tube Automatic Fire Suppression System / Automatic Tube Fire Extinguisher,
CAFS Fire Systems (Compressed Air Foam Fire System),
Stainless Steel Fire Extinguisher,
Throwing Fire Extinguisher,
Cooking Oil Fire Extinguisher,Fire Extinguisher,etc.
Our products are mainly export to Europe, Middle east, America, South America, Africa, etc. Most of our products are with approval of CE, UN ECE R107, China CCC, UL, etc. We produce high quality fire fighting products, and we supply one-stop purchasing service too.

 
4.2MPa 180L FM200 Hfc-227ea Total Flooding Fire System Extinguisher System FM200 Automatic Fire Suppression System Stainless Steel Fire Extinguisher Cylinder

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier