Cabinet Type Fk5112 Total Flooding Fire System

Product Details
Customization: Available
Agent: Clean Agent
Type: Automatic
Still deciding? Get samples of $ !
Request Sample

360° Virtual Tour

Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
886813.09 USD
Management System Certification
ISO9001:2015
  • Cabinet Type Fk5112 Total Flooding Fire System
  • Cabinet Type Fk5112 Total Flooding Fire System
  • Cabinet Type Fk5112 Total Flooding Fire System
  • Cabinet Type Fk5112 Total Flooding Fire System
  • Cabinet Type Fk5112 Total Flooding Fire System
  • Cabinet Type Fk5112 Total Flooding Fire System
Find Similar Products
  • Overview
  • Product Description
  • Features
  • Product Parameters
  • Packing
  • Fire Alarm System
  • Company Profile
Overview

Basic Info.

Object
Class a, B, C
Certification
CCC
Retirement Life
8 Years
Power Source
Pressure Fire Extinguisher
Fire Agent
Fk5112
Application
Bank Vaults Libraries Book Stores Electronic Dat
Raw Material of Cylinder
Stainless Steel
Filling Pressure
4.2MPa
Max Working Pressure
5.6MPa
Gas Type
Clean Agent
Transport Package
Professional Export Carton/Pallet
Specification
70L, 90L, 100L, 120L, 150L, 180L
Trademark
PRI-SAFETY
Origin
Hangzhou, China
HS Code
84241000
Production Capacity
100000 Units/Year

Product Description

Cabinet Type FK5112 Total Flooding Fire System

Product Description

 

Cabinet Type Fk5112 Total Flooding Fire System
Cabinet Type Fk5112 Total Flooding Fire System

 

PRI-SAFETY FK5112 Total Flooding Fire System Gas Suppression Systems (FK5112) is a reliable solution based on FK5112, an extinguishing agent known around the world.  Built on 42-bar technology, these Gas Suppression Systems are efficient and space-saving.  Whether for the valuable systems, data, people or the working environment, this Gas Suppression System provides optimum protection in case of fire and helps ensuring business continuity.  The extinguishing agent of this Gas Suppression System is very effective and works at low extinguishing concentrations to protect people and assets.  The extinguishing agent is chemically inert and has low electric conductivity.  This Gas Suppression Systems provides ideal protection especially for areas with electrical and electronic risks of fire.  Extinguishing without leaving any residue and without risking of corrosion is found in this Gas Suppression System.

Working Principle:
PRI-SAFETY FK5112 Total Flooding System / Data Center Fire Protection System FK5112 Fire Extinguisher System are generally used in conjunction with fire detectors, fire alarm fire extinguishing controllers, emergency start/stop buttons, sound and light alarms, deflation indicators and other fire fighting equipment. When a fire occurs in the protection area, the temperature and smoke detectors will send out a fire signal. After the logic analysis of the automatic fire alarm and extinguishing controller, it will send out a sound and light composite alarm signal, and at the same time send out a linkage command to turn off the linkage equipment. After a delay time, a fire extinguishing command is issued, the solenoid valve driver is opened, the container valve is opened, the fire extinguishing agent is released, and the fire is extinguished; if the duty officer discovers a fire, he can press the emergency start button outside the protective area door to implement the fire extinguishing operation ; There is also a manual button on the solenoid valve driver, and mechanical emergency manual operation can also be used to extinguish fire in an emergency.

 

Features

--Very swift fire suppression.
--Reach extinguishing level ≤10s.
--Safe to people. People is safe when exposed at the FK5112 gas discharge level.
--Low extinguishing concentration. Nearly no obscure to vision in person evacuation.
--Easy to clean. No residue left, and minimize damage to sensitive equipment.
--Environment friendly. Zero ozone depletion potential and zero global warming potential.
--Simple installation, with small storage space.

Product Parameters

Whole Fire System's specification:

Filling Pressure 2.5Mpa, 4.2Mpa
Max Working Pressure 4.2Mpa, 5.6Mpa
Capacity of FK5112 Cylinder 40L, 70L, 90L, 120L, 150L, 180L, 250L, 345L, 500L
Material of Cylinder Stainless Steel
Valve Brass or Stainless Steel
Fire Agent FK5112, UL and FM Listed



PRI-SAFETY FK5112 Total Flooding Fire System, contain: FK5112 cylinder, diptube, head valve, solenoid valve, pressure gauge, high pressure pipe, liquid check valve, gas check valve, control gas pipe, nozzle, pressure switch, safety valve, low discharge high seal valve, select valve, N2 cylinder with solenoid valve, pipes. 


1. Specification of FK5112 Cylinder(70L, 90L, 100L, 120L, 150L, 180L, 250L, 345L, 500L):

Cabinet Type Fk5112 Total Flooding Fire System



2. Valve's specification:

For PRI-SAFETY FK5112 Total Flooding Fire System, its head valve with solenoid valve, we have two model: normal quality model, high quality model. its specification as below:

Normal Quality Valve
Cabinet Type Fk5112 Total Flooding Fire System

 

Item DN32 DN40 DN50
Code NO.

V32/4.2-PRI

V32/5.3-PRI

V40/4.2-PRI

V40/5.3-PRI

V50/4.2-PRI

V50/5.3-PRI

Neck Thread PZ56 M64X2 M80X2
Actuator Thread M18X1.5 M18X1.5 M18X1.5
Diptube Thread RC 1-1/4'' RC 1-1/2'' RC 2''
High Pressure flexible thread M48X2 M56X2 M68X2
Pressure gauge thread M10x1 M10x1 M10x1
Working Pressure 4.2Mpa/5.3Mpa 4.2Mpa/5.3Mpa 4.2Mpa/5.3Mpa
Applicable cylinder <=100L 120L 150L 180L 250L
 
 
High Quality Valve
Cabinet Type Fk5112 Total Flooding Fire System
Cabinet Type Fk5112 Total Flooding Fire System
 

 

Code No.

AV25/4.2-PRI

AV25/5.3-PRI

AV50/4.2-PRI

AV50/5.3-PRI

Item G1'' G2''
Neck thread 2-8UN.2A 3 1/4-8UN.2A
Actuator thread G1'' G1''
High pressure flexible thread G1'' G2''
Pressure gauge thread 1/8'' NPT 1/8'' NPT
Working pressure  6.7Mpa 6.7Mpa
Test pressure 10.05Mpa 10.05Mpa
Applicable cylinder <=70L 90L 120L 150L 180L


 

Single Bottle Model With or Without Pilot Cylinder:

 

Cabinet Type Fk5112 Total Flooding Fire System
To FK5112 Total Flooding Fire System,  its head valve is with solenoid valve. When the detector detects a fire signal, it sends a signal to the controller. When the controller receives the signal, it will activate the solenoid valve, which will then open the valve, and the extinguishing agent will go from the bottle to the tube to extinguish the fire.
 

 


 

 

Packing

Cabinet Type Fk5112 Total Flooding Fire System
Fire Alarm System

For PRI-SAFETY FK5112 Total Flooding Fire Systen, its control panel and fire alarm system contain Addressable Control Panel, Smoke detector, Heat Detector, Alarm(Siren/Light), Emergency Start/Abort Switch, Auto/Manual Switch Module, Discharge Indicate Light, I/O Module, etc. 
Cabinet Type Fk5112 Total Flooding Fire System

Company Profile

PRI-SAFETY FIRE TECHNOLOGY is Establised in 2005, is Focused on Automatic Fire Suppression Systems and Fire Equipment R&D, Design and Manufacture.

The Main Products are On/Off Road Vehicles & Machines Automatic Fire Suppression system, HFC-227ea & FK-5112 Clean gas Fire Suppression systems, CAFS( Mobile Compressed Air Foam System),  Water Mist Fire System, Foam Mist Fire System, Co2 Fire System, etc. 

The Products and Fire Systems are used in Mining Industry, Forest Industry, Agriculture, Petrochemical, Transportation, Electricity Power, Industry,Construction and other fields.

PRI-SAFETY Has Professional Technology Team , Have Ability Supply Design, Solution, and Customization, For Special Project Requirement, and Technology Training&Instruction After Sales.

PRI-SAFETY Has the Certificates,  ISO9001:2015, TUV CE0036, ECE R107, CCC, and So On. The Products Meet the International Standard of EN, NFPA, CNAS,ECE, etc.

Cabinet Type Fk5112 Total Flooding Fire System


 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier