Nfpa750 Standard High-Pressure Water Mist Fire System for Electrical Distribution Room It Industry
|
Still deciding? Get samples of $ !
Order Sample
|
| Customization: | Available |
|---|---|
| Sprinkler Installation: | Upright |
| Sprinkler Head Type: | Closed |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
360° Virtual Tour
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
CE
Fire Protection Product Certification
Find Similar Products
Basic Info.
- Alarm Valve Type
- Wet Alarm Valve
- Automatically Opened and Closed Repeatedly
- Can Automatically Opened and Closed
- Open Fire Sprinkler System Type
- Deluge System
- Closed Fire Sprinkler System
- Wet Fire Sprinkler System
- Dry Alarm Valve Type
- Differential Type
- Wet Alarm Valve Structure
- Seat Type
- Alarm Valve Diameter
- 150mm
- Nozzle Flow Coefficient
- 115
- Deluge Valve Type
- Thermal Type
- Material
- Carbon Steel
- Transport Package
- Wooden
- Trademark
- Pri-safety
- Origin
- Zhejiang
- HS Code
- 84241000
- Production Capacity
- 100000
Packaging & Delivery
- Package Size
- 200.00cm * 250.00cm * 200.00cm
- Package Gross Weight
- 1200.000kg
Product Description
NFPA STANDARD PUMP-TYPE WATER MIST FIRE SYSTEM

The high-pressure fine water mist fire extinguishing system uses a dedicated pump set to pressurize water to 10MPa or more, and then sprays it out through specially designed fine water mist nozzles. After coming into contact with the flame, these fine water mists rapidly vaporize, absorbing a large amount of heat and causing a sudden drop in the temperature of the burning material.
Meanwhile, the water vapor produced by vaporization will dilute the oxygen concentration and inhibit the combustion reaction. The fine water mist can also block heat radiation and prevent the spread of fire, thus achieving efficient fire suppression.

A water mist system is a fire protection system which uses very fine water sprays (i.e. water mist). The small water droplets allow the water mist to control, suppress or extinguish fires by:
- Cooling both the flame and surrounding gases by evaporation
- Displacing oxygen by evaporation
- Attenuating radiant heat by the small droplets themselves
The effectiveness of a water mist system in fire suppression depends on its spray characteristics, which include the droplet size distribution, flux density and spray dynamics, with respect to the fire scenario, such as the shielding of the fuel, fire size and ventilation conditions.
Product Advantages
- Immediate activation
- High efficiency in the suppression of a wide variety of fires
- Minimized water damage
- Environmentally sound characteristics
- No toxic problems
Reduces Post Water Damage: Water Mist Systems use a fraction of the amount of water conventional water sprinkler systems use which minimizes any water damage and reduces water run-off.
Environmentally Friendly : Utilizing minimal water and reducing the need for cleanup ensuring minimal environmental impact.
Cost Effective : Low cost and expense for small volumes of potable water.
So really high pressure system, specialized tubing or piping that's used for that. Now, there are differences between water mist systems and the droplet sizes that they produce, so typically the smaller the water droplet size the better it is at extinguishing a hot fire. Larger droplets can work faster on lower temperature fires, but they all work for the systems that they're approved for or listed for.

Water Mist Fire System are generally used in conjunction with fire detectors, fire alarm fire extinguishing controllers, emergency start/stop buttons, sound and light alarms, deflation indicators and other fire fighting equipment. When a fire occurs in the protection area, the temperature and smoke detectors will send out a fire signal. After the logic analysis of the automatic fire alarm and extinguishing controller, it will send out a sound and light composite alarm signal, and at the same time send out a linkage command to turn off the linkage equipment. After a delay time, a fire extinguishing command is issued, the solenoid valve driver is opened, the container valve is opened, the fire extinguishing agent is released, and the fire is extinguished; if the duty officer discovers a fire, he can press the emergency start button outside the protective area door to implement the fire extinguishing operation ; There is also a manual button on the solenoid valve driver, and mechanical emergency manual operation can also be used to extinguish fire in an emergency.
NFPA750 Pump Type High Pressure Water Mist Fire System
| Pump Pressurized Type Water Mist Fire System | |||||
|
Code Number |
Working Pressure |
Flow(L/Min) | Pump Speed(r/Min) |
Dimension(mm) |
Note |
|
XSWBG112/14-PRI |
14MPa |
112 |
1470 |
2200x1200x2000 |
One Work One Spare |
|
XSWBG224/14-PRI |
14MPa |
224 |
1470 |
2650x1200x2000 |
Two Work One Spare |
|
XSWBG336/14-PRI |
14MPa |
336 |
1470 |
2650x1200x2000 |
Three Work One Spare |
|
XSWBG448/14-PRI |
14MPa |
448 |
1470 |
3100x1200x2000 |
Four Work One Spare |
|
XSWBG560/14-PRI |
14MPa |
560 |
1470 |
3100x1200x2000 |
Five Work One Spare |
|
XSWBG672/14-PRI |
14MPa |
672 |
1470 |
3550x1200x2000 |
Six Work One Spare |
|
XSWBG784/14-PRI |
14MPa |
784 |
1470 |
3550x1200x2000 |
Seven Work One Spare |
Pump control cabinet
The control cabinet of the high-pressure water mist pump unit is composed of star-delta controller, programmable controller, sensor, control circuit, and cabinet.
Water Mist Nozzles
Open Type
plurality of centrifugal nozzles installed on the conical surface of the shell.
The atomization mechanism is to utilize the rotating liquid produced by the swirling parts in the nozzle to accelerate and eject
the hollow diffusion cone-shaped liquid film through the outlet channel, and use the speed difference between the liquid and the
outside air to break up and atomize.While on stand-by, our system boasts dry piping for maximum efficiency. Activation can be
achieved manually or through the sensors that detect heat, smoke, or flames - tailored to your specific needs.
Our nozzles are thoughtfully grouped in sections, so upon activation, all nozzles within the selected section will be released for
optimal fire suppression.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Close Type nozzle
While in standby mode, our system maintains a pipe pressure of approximately 12 bar. Once the temperature surpasses 57°C, the heat-sensitive glass bulbs integrated into the nozzle heads will begin to melt. As a result, the high-pressure pump will be automatically activated, forcing water through high-pressure nozzles (60 or 100 bar, depending on nozzle type) to produce a fine mist. Only those nozzles with melted bulbs will activate, ensuring that only the affected area is actively sprayed.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Water Supply: Tanks or connected sources, often requiring minimal water volume compared to traditional systems.
| Project installation example |
1. Commercial Settings Data Centers:Protects sensitive electronics with minimal water damage.Hospitals: Ensures fire suppression without disrupting medical equipment or patient safety.Museums/Libraries: Safeguards artifacts and books by minimizing water exposure.Shopping Malls/Office Buildings: Efficiently controls fires while reducing collateral damage. 2. Industrial Environments Oil & Gas Facilities: Suppresses flammable liquid/gas fires without spreading hazards.Power Plants: Protects turbines and generators; effective in controlling high-heat fires.Manufacturing Plants: Ideal for machinery spaces with overheating risks.Pharmaceutical Clean Rooms: Prevents contamination while suppressing fires.
3. Transportation Marine Vessels: Uses seawater in confined spaces (engine rooms, cargo holds).Aircraft Hangars: Safeguards expensive equipment and complies with aviation safety standards.Tunnels: Functions effectively in ventilated or underground environments.Rail/Public Transit: Deployed in stations or trains for rapid response.
| Work Shop |
-
Maintenance and Servicing: Water mist system maintenance checklist, how to refill water mist cylinders.
-
Installation Design: Water mist system hydraulic calculation, cost of installing water mist system per square meter.
-
Advantage Consulting: Why use water mist instead of gas suppression, water damage comparison fire sprinkler vs water mist.
PRI-SAFETY Supply Project Design, Technology Solution, Manufacturer & Customization, Training and Installation Instruct.
PRI-SAFETY was established in 2004, is professional manufacturer of FM200 HFC227EA Fire Suppression System,
Automatic Fire Suppression System (For Kitchen. For Vehicle, For Electrical Devices),
CO2 Total Flooding Fire System,
Tube Automatic Fire Suppression System / Automatic Tube Fire Extinguisher,
CAFS Fire Systems (Compressed Air Foam Fire System),
Stainless Steel Fire Extinguisher,
Throwing Fire Extinguisher,
Cooking Oil Fire Extinguisher,Fire Extinguisher,etc.
Our products are mainly export to Europe, Middle east, America, South America, Africa, etc. Most of our products are with approval of CE, UN ECE R107, China CCC, UL, etc. We produce high quality fire fighting products, and we supply one-stop purchasing service too.
Send your message to this supplier
People who viewed this also viewed
Product Groups
Find Similar Products By Category
- Supplier Homepage
- Products
- 13. Water Mist Fire System
- Pump Type Water Mist Fire System
- Nfpa750 Standard High-Pressure Water Mist Fire System for Electrical Distribution Room It Industry