Customized High Pressure Water Mist Fire System

Product Details
Customization: Available
Agent: Water
Certification: CE
Still deciding? Get samples of $ !
Request Sample

360° Virtual Tour

Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
886813.09 USD
Management System Certification
ISO9001:2015
  • Customized High Pressure Water Mist Fire System
  • Customized High Pressure Water Mist Fire System
  • Customized High Pressure Water Mist Fire System
  • Customized High Pressure Water Mist Fire System
  • Customized High Pressure Water Mist Fire System
  • Customized High Pressure Water Mist Fire System
Find Similar Products

Basic Info.

Model NO.
WM/PRI-112/14
Effective Range
9m
Retirement Life
5 Years
Transport Package
Shipping Pallet
Specification
70L, 80L, 90L, 100L, 120L
Trademark
PRI-SAFETY
Origin
China
HS Code
84241000
Production Capacity
5000

Product Description

Customized High Pressure Water Mist Fire System
Customized High Pressure Water Mist Fire System
Customized High Pressure Water Mist Fire System

 
Product Description
Water Mist Fire System is a Fixed Completely System, Designed with Water Mist tank, Nitrogen Gas Propellant Bottles, Pressure Regulator, Safety Valve, Nozzles, Detectors, Fire Alarm, Control Panel, etc. The System can be activated by detectors automatically, and also by hand.
Specification
 
The high-pressure fine water mist fire extinguishing system uses a dedicated pump set to pressurize water to 10MPa or more, and then sprays it out through specially designed fine water mist nozzles. After coming into contact with the flame, these fine water mists rapidly vaporize, absorbing a large amount of heat and causing a sudden drop in the temperature of the burning material.

Meanwhile, the water vapor produced by vaporization will dilute the oxygen concentration and inhibit the combustion reaction. The fine water mist can also block heat radiation and prevent the spread of fire, thus achieving efficient fire suppression.
 
Water Mist Fire System is a Fixed Completely System, Designed with Water Mist tank, Nitrogen Gas Propellant Bottles, Pressure Regulator, Safety Valve, Nozzles, Detectors, Fire Alarm, Control Panel, etc. The System can be activated by detectors automatically, anPump Pressurized Type Water Mist Fire System
Single Pump, 112L/Min, 14Mpa, 30KW
 
Working Pressure
Flow
(L/Min)
Pump Speed
(R/Min)
Dimension
(mm)
Note
WM/PRI-112/14
14Mpa
112
1470
2200x1200x2000
One Work One Reserve
WM/PRI-224/14
14Mpa
224
1470
2650x1200x2000
Two Work One Reserve
WM/PRI-336/14
14Mpa
336
1470
2650x1200x2000
Three Work One Reserve
WM/PRI-448/14
14Mpa
448
1470
3100x1200x2000
Four Work One Reserve
WM/PRI-560/14
14Mpa
560
1470
3100x1200x2000
Five Work One Reserve
WM/PRI-672/14
14Mpa
672
1470
3550x1200x2000
Six Work One Reserve
WM/PRI-784/14
14Mpa
784
1470
3550x1200x2000
Seven Work One Reserve

Pump Pressurized Type Water Mist Fire System

Single Pump, 134L/Min, 16Mpa, 45KW
Code Number
Working
Pressure
Flow
(L/Min)
Pump Speed
(R/Min)
Dimension
(mm)
Note
WM/PRI-134/16
16Mpa
134
1470
2200x1200x2000
One Work One Reserve
WM/PRI-268/16
16Mpa
268
1470
2650x1200x2000
Two Work One Reserve
WM/PRI-402/16
16Mpa
402
1470
2650x1200x2000
Three Work One Reserve
WM/PRI-536/16
16Mpa
536
1470
3100x1200x2000
Four Work One Reserve
WM/PRI-670/16
16Mpa
670
1470
3100x1200x2000
Five Work One Reserve
WM/PRI-804/16
16Mpa
804
1470
3550x1200x2000
Six Work One Reserve
WM/PRI-938/16
16Mpa
938
1470
3550x1200x2000
Seven Work One Reserve

Pump Pressurized Type Water Mist Fire System

Single Pump, 168L/Min, 13Mpa, 45KW
Code Number
Working Pressure
Flow
(L/Min)
Pump Speed
(R/Min)
Dimension
(mm)
Note
WM/PRI-168/13
13Mpa
168
1470
2200x1200x2000
One Work One Reserve
WM/PRI-336/13
13Mpa
336
1470
2650x1200x2000
Two Work One Reserve
WM/PRI-504/13
13Mpa
504
1470
2650x1200x2000
Three Work One Reserve
WM/PRI-672/13
13Mpa
672
1470
3100x1200x2000
Four Work One Reserve
WM/PRI-840/13
13Mpa
840
1470
3100x1200x2000
Five Work One Reserve
WM/PRI-1008/13
13Mpa
1008
1470
3550x1200x2000
Six Work One Reserve
WM/PRI-1176/13
13Mpa
1176
1470
3550x1200x2000
Seven Work One Reserve
Working Principle:
Water Mist Fire Systemare generally used in conjunction with fire detectors, fire alarm fire extinguishing controllers, emergency start/stop buttons, sound and light alarms, deflation indicators and other fire fighting equipment. When a fire occurs in the protection area, the temperature and smoke detectors will send out a fire signal. After the logic analysis of the automatic fire alarm and extinguishing controller, it will send out a sound and light composite alarm signal, and at the same time send out a linkage command to turn off the linkage equipment. After a delay time, a fire extinguishing command is issued, the solenoid valve driver is opened, the container valve is opened, the fire extinguishing agent is released, and the fire is extinguished; if the duty officer discovers a fire, he can press the emergency start button outside the protective area door to implement the fire extinguishing operation ; There is also a manual button on the solenoid valve driver, and mechanical emergency manual operation can also be used to extinguish fire in an emergency.
No.
Item
Technical Parameter
1
Code No.
WM-nx70/5.3-PRI
WM-nx90/5.3-PRI
WM-nx120/5.3-PRI
WM-nx150/5.3-PRI
WM-nx180/5.3-PRI
2
Working Pressure
5.3Mpa
3
Water Capacity
Nx70L
Nx90L
Nx120L
Nx150L
Nx180L
4
Discharge duration
10 minutes
 
Working Principle:
 
Water Mist Fire Systemare generally used in conjunction with fire detectors, fire alarm fire extinguishing controllers, emergency start/stop buttons, sound and light alarms, deflation indicators and other fire fighting equipment. When a fire occurs in the protection area, the temperature and smoke detectors will send out a fire signal. After the logic analysis of the automatic fire alarm and extinguishing controller, it will send out a sound and light composite alarm signal, and at the same time send out a linkage command to turn off the linkage equipment. After a delay time, a fire extinguishing command is issued, the solenoid valve driver is opened, the container valve is opened, the fire extinguishing agent is released, and the fire is extinguished; if the duty officer discovers a fire, he can press the emergency start button outside the protective area door to implement the fire extinguishing operation ; There is also a manual button on the solenoid valve driver, and mechanical emergency manual operation can also be used to extinguish fire in an emergency.
 
Product Photo:
Company information:
PRI-SAFETY FIRE TECHNOLOGY is Establised in 2005, is Focused on Automatic Fire Suppression Systems and Fire Equipment R&D, Design and Manufacture.
The Main Products are On/Off Road Vehicles & Machines Automatic Fire Suppression system, HFC-227ea & FK-5112 Clean gas Fire Suppression systems, CAFS( Mobile Compressed Air Foam System),  Water Mist Fire System, Foam Mist Fire System, Co2 Fire System, etc. 

The Products and Fire Systems are used in Mining Industry, Forest Industry, Agriculture, Petrochemical, Transportation, Electricity Power, Industry,Construction and other fields.

PRI-SAFETY Has Professional Technology Team , Have Ability Supply Design, Solution, and Customization, For Special Project Requirement, and Technology Training&Instruction After Sales.

PRI-SAFETY Has the Certificates,  ISO9001:2015, TUV CE0036, ECE R107, CCC, and So On. The Products Meet the International Standard of EN, NFPA, CNAS,ECE, etc.

 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier