Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms

Still deciding? Get samples of $ !
Order Sample
Product Details
Customization: Available
Agent: FM200/Hfc-227ea Fk-5112 Novec 1230
Type: FM200/Hfc-227ea Fk-5112 Novec 1230
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
T/T PayPal ApplePay GooglePay visa mastercard american express discover
JCB diners club PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 2 R&D engineers, you can check the Audit Report for more information
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
Fire Protection Product Certification
to see all verified strength labels (23)
  • Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
  • Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
  • Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
  • Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
  • Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
  • Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Find Similar Products
  • Overview
  • Product Description
  • PRI-SAFETY Design Drawing
  • Specification
  • Production Process (Factory)
  • Packing & Shipping
  • Application
  • FAQ
  • Company Profile
Overview

Basic Info.

Model NO.
Novec 1230 Fire System
Object
Class a/B/C/D/E Fire
Size
Customized
Certification
CCC, ISO9001
Portable Extinguisher
Auomatic Fire Extinguisher
Effective Range
/
Retirement Life
8 Years
Dry Powder Type
FM200/Hfc-227ea Fk-5112 Novec 1230
Power Source
Gas Fire Extinguisher
Product Name
FM200/Hfc-227ea Fire Suppression System
Capacity
Need Customized One-to-One According to The Scene
Application
Class a/B/C/D/E Fire
Filling Pressure
2.5MPa/4.2MPa/5.6MPa
Max Working Pressure
4.2MPa/5.6MPa/8MPa
Extinguisher Model
Automatic
Brand Name
Pri-Safety
Certificate
China CCC Certificated
OEM
Support
Transport Package
High Quality Export Carton Box
Specification
Customized
Trademark
PRI-SAFETY
Origin
China
HS Code
84241000
Production Capacity
50000pieces/Month

Packaging & Delivery

Package Size
135.00cm * 138.00cm * 58.00cm
Package Gross Weight
138.000kg

Product Description

Product Description
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
FK5112 System Novec1230 Automatic Fire Suppression System Clean Agent FM200 Fire System for Data Center
1. What is the FM200 Novec 1230 Fire Suppression System?
Our FM200 Fire Suppression System (HFC-227ea) and NOVEC 1230 / FK5112 Fire Suppression System are advanced clean agent fire suppression systems designed  in accordance with NFPA 2001 standards, for fast, reliable, and residue-free fire protection. These systems are widely used in critical environments where water-based fire fighting systems are not suitable.
Both FM200 and NOVEC 1230 systems suppress fire by absorbing heat and interrupting the combustion process, providing rapid fire extinguishing without damaging sensitive equipment. They are compliant with international standards and commonly selected for data centres, server rooms, electrical control rooms, and clean rooms.
This product range is ideal for distributors, contractors, EPC companies, and fire protection integrators.
At present, we have designed two types of appearance of cabinet and pipe network, and divided into a single bottle group, multi-bottle group has different size specifications, can be used for different occasions.
When the control mode selection key on the automatic fire alarm and fire extinguishing controller is set to the "auto" position, the fire extinguishing system is under automatic control. When a fire occurs in the protection area, the temperature and smoke detectors will send out a fire signal through the automatic fire alarm and extinguishing control After the logic analysis of the device, it sends out a combined sound and light alarm signal, and sends out a linkage command at the same time to close the linkage device. After a delay, a fire extinguishing command is issued, the starting valve is opened to release the starting gas, and the starting gas is opened through the control gas pipeline valves and container valves release the fire extinguishing agent and implement fire extinguishing.
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
PRI-SAFETY Design Drawing
We provide one-stop fire suppression solutions.
The clean agent fire suppression system is typically installed as a total flooding system:
Agent cylinders installed inside or near the protected area
Piping network connected to discharge nozzles
Fire detection system (smoke detector / heat detector)
Control panel for automatic and manual activation
Typical installation areas include:
Server room ceiling-mounted nozzles
Electrical cabinet or power room wall-mounted systems
Data centre raised floor or ceiling void protection
The system can be configured for single-zone or multi-zone protection depending on room volume and risk level.
One-Stop Fire Protection Solution from Design to Training
We provide a complete one-stop service, covering project design, customized manufacturing, installation support and technical training, ensuring smooth delivery from concept to operation.
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
PRI-SAFETY FK5112 FM200 HFC-227EA Clean Agent Fire Suppression System FM200 Fire System Advantage:
*Clean Agent Technology – No residue, no secondary damage
*Fast Discharge – Fire suppression within seconds
*Safe for Occupied Spaces – Designed for human presence
*Non-Conductive – Ideal for electrical and electronic equipment
*Compact Design – Space-saving cylinder options
*Low Maintenance – Long service life and stable performance
*Compatible with International Standards – Suitable for global projects
FM200 and NOVEC 1230 fire systems are widely recognized as reliable alternatives to traditional CO2 and water-based fire fighting systems.
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Installation FM200 FK5112 Fire System Case For Data center:
PRI-SAFETY Supply Project Design, Technology Solution, Produce & Customization, Training and Installation Instruct.
If you have any installation question our technical person will offer a quick-response guidance.
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Specification
Need Customized one-to-one according to the scene
Clean agent: FM200 (HFC-227ea) / NOVEC 1230 (FK5112)
Discharge time: ≤10 seconds
Operating mode: Automatic / Manual / Emergency release
System type: Total flooding fire suppression system
Suitable for electrical fire fighting and enclosed spaces
The specific specifications need to be customized one-to-one according to the scene you use and the height and size of the site.
If you have any needs, please contact us and we will customize a solution for you. The above is the specification details of Cylinder Specification---4.2MPa/5.6MPa(Filling Pressure)
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Carbon Steel Material + American Valve
Stainless Steel Material + American Valve
Carbon Steel Material + Normal Valve
Technical Specifications
FM200/Novec1230 Cylinder Specification---4.2MPa/5.6MPa
NO.
Specification
Technical Parameter
1
Filling pressure
4.2Mpa
5.6Mpa
2
Scale of Protective region for one zone
Area:max single-zone is 800m² volume:max single-zone is 3600m³
3
Spraying time
10s
4
Filling density
≤950kg/m3
≤1080kg/m3
5
Power
DC24V/1.6A
6
Nitrogen Pressure of Driving Device
6.0±1.0Mpa(20ºC)
7
Condition of reserving room for container
temperature: -10~50ºC, relative humidity: ≤97%
8
Max working pressure
5.6Mpa
8.0Mpa
9
Min working pressure
4.2Mpa
5.6Mpa
10
Capacity
16/32/40/70/82.5/90/100/120/140/150/250/345/350/450/500 L
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Novec 1230 FK5112 System Main Components
 Some accessories are available in multiple widths
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Production Process (Factory)
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Packing & Shipping
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Application
What FM200 HFC227EA/FK5112 Novec1230 Fire System can be used for:
FM200 HFC227EA/FK5112 Novec1230 Total Flooding Fire System is designed for fire protection in various applications, especially in environments where the use of water-based systems is not suitable or could cause damage to sensitive equipment.
*Data Centre & Server Room: Protect servers, storage devices, network equipment, Prevent water damage to IT infrastructure, Used in hyperscale data centres and telecom rooms
*Archives & Cultural Heritage: Museums, libraries, archive rooms, Protection of valuable documents, books, artworks, No residue or moisture damage
*Laboratory & Medical Facilities: Research laboratories, Medical equipment rooms, Protection of precision instruments, chemicals, and biological samples
*Electronics Manufacturing & Control Rooms: Clean rooms and automation control rooms, PLC cabinets, MCC rooms, SCADA control centres, Prevent damage to sensitive electronics
*Power Facilities: Power plants and substations, Electrical distribution panels and control rooms, Generator rooms and UPS rooms
*Aerospace: Aircraft electronic bays, Ship control rooms and equipment compartments
*Oil, Gas & Marine: Offshore drilling platforms, Marine engine rooms, Oil & gas control modules and electrical rooms
*Power plants, offshore power platforms, control rooms and substations, high and low voltage power distribution rooms/control rooms, hospitals, energy storage cabinets, high-speed rail stations/subway stations.
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
FAQ
FAQ of  FM200 and NOVEC 1230 fire systems
Q1: What is the difference between FM200 and NOVEC 1230 fire systems?
FM200 uses HFC227ea, while NOVEC 1230 uses FK5112 clean agent. NOVEC 1230 has lower environmental impact, while FM200 is widely used and cost-effective.
Q2: Is this system safe for people?
Yes. Both FM200 and NOVEC 1230 fire suppression systems are designed for occupied spaces when properly installed.
Q3: Can the system be customized for different room sizes?
Yes. Cylinder capacity, piping, and nozzle layout can be designed based on room volume and fire risk.
Q4: Is this suitable for data centres and server rooms?
Absolutely. Clean agent fire suppression systems are one of the most common fire fighting systems used in data centres and IT rooms.
Q5: Can this system replace CO2 or water mist systems?
In many electrical and electronic applications, FM200 and NOVEC 1230 systems are preferred alternatives due to safety and zero residue.
Q6: What working pressure options are available for FM200 cylinders?
We offer FM200 cylinders with:
4.2MPa working pressure
5.6MPa working pressure
8.0MPa working pressure
Different pressure options allow flexible system design for various room sizes and piping distances.
Q12: Do you provide system design and installation support?
Yes. We provide a complete one-stop service, including:
System design
Manufacturing
Installation guidance or on-site support
Technical training (online and on-site)
Q17: Can you provide drawings and technical documents before ordering?
Yes. We can provide:
System layout drawings
Piping and nozzle distribution drawings
Wiring diagrams
Technical datasheets
Q13: Can you provide OEM or customized FM200 systems?
Yes. Such as:
Customized cylinder sizes
Private labeling
Special pressure requirements
Project-specific system configurations
Q18: How can I choose the right FM200 system for my project?
Simply contact us with:
Room dimensions
Application type
Number of rooms
Local standards
Our engineers will provide a customized FM200 fire suppression solution tailored to your project.
Company Profile
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
PRI-SAFETY FIRE TECHNOLOGY CO., LTD.
PRI-SAFETY factory was built in 2005, is a national high-tech enterprise focusing on the research, design and manufacture of automatic fire suppression systems and fire fighting equipment.
 
And the main products we produce include : Vehicle and Mechanical Equipment Automatic Fire Suppression System, Kitchen Fire System, Heptafluoropropane Gas Fire Suppression System, FM200/FK-5112 Tool Flooding System, Water Mist Fire System, Compressed Air Foam Equipment(CAFS), Fire Trace Fire system, etc
 
We not only produce fire system but also design them and provide various fire solution, we have a professional technical team to help us with that, and also perfect aftersale-service.
Any question, like installlation, feel free to contact us, we are always online. And we has passed ISO9001:2015 quality management system certification, and its has CE and EN certification, UN ECE R107 certificate for vehicle safety.
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Why Choose Us?
Other Services
One-Stop Fire Protection Solution from Design to Training
Our Novec 1230 FK5112 HFC227EA FM200Fire Suppression System is a proven total flooding clean agent solution designed for fast and reliable fire protection in large and complex enclosed spaces.
We provide a complete one-stop service, covering project design, customized manufacturing, installation support and technical training, ensuring smooth delivery from concept to operation.
This system uses FK-5112/FM200, a clean, residue-free and electrically non-conductive fire extinguishing agent, widely applied in data centers, electrical rooms and industrial control environments.
 
One-Stop Service Capability
We are not only a manufacturer, but a full-solution provider of Novec 1230 FK5112 HFC227EA FM200Fire Suppression System
* Project Design & Engineering
System design according to NFPA 2001
Engineering design for single-room and multi-room total flooding systems
* Customized Manufacturing
In-house production of FK5112 Novec1230 cylinders, valves, manifolds, hoses and nozzles, 4.2MPa / 5.6MPa / 8.0MPa working pressure options
OEM / ODM customization and private labeling available
ISO9001 quality management with CCC certified components
* Installation & Commissioning Support
On-site installation guidance or complete installation service
System commissioning, pressure testing and functional verification
Remote technical support for overseas FK5110 Novec 1230 FM200projects
* Technical Training (Online & On-site)
Online technical training for distributors and contractors
On-site training for large-scale fire suppression projects
Operation, maintenance and troubleshooting guidance
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms
Novec 1230 Fire System Fk5-1-12 for High-Speed Rail Control Rooms

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now