Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room

Product Details
Customization: Available
Sprinkler Installation: Upright
Sprinkler Head Type: Closed

360° Virtual Tour

Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
886813.09 USD
Management System Certification
ISO9001:2015
  • Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room
  • Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room
  • Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room
  • Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room
  • Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room
  • Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room
Find Similar Products
  • Overview
  • Product Description
  • Advantages
  • Working Principle
  • Product Parameters
  • Main Components
  • Details Pictures
  • Product Application
  • Company Profile
Overview

Basic Info.

Alarm Valve Type
Wet Alarm Valve
Automatically Opened and Closed Repeatedly
Can Automatically Opened and Closed
Open Fire Sprinkler System Type
Deluge System
Closed Fire Sprinkler System
Wet Fire Sprinkler System
Dry Alarm Valve Type
Differential Type
Wet Alarm Valve Structure
Seat Type
Alarm Valve Diameter
150mm
Nozzle Flow Coefficient
115
Deluge Valve Type
Thermal Type
Transport Package
Wooden
Trademark
Pri-safety
Origin
Zhejiang
HS Code
84241000
Production Capacity
100000

Product Description

 
 

                                    NFPA STANDARD PUMP-TYPE WATER MIST FIRE SYSTEM
 

Product Description

Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room
The high-pressure fine water mist fire extinguishing system uses a dedicated pump set to pressurize water to 10MPa or more, and then sprays it out through specially designed fine water mist nozzles. After coming into contact with the flame, these fine water mists rapidly vaporize, absorbing a large amount of heat and causing a sudden drop in the temperature of the burning material.


Meanwhile, the water vapor produced by vaporization will dilute the oxygen concentration and inhibit the combustion reaction. The fine water mist can also block heat radiation and prevent the spread of fire, thus achieving efficient fire suppression.
 
Water Mist Fire System is a Fixed Completely System, Designed with Water Mist tank, Nitrogen Gas Propellant Bottles, Pressure Regulator, Safety Valve, Nozzles, Detectors, Fire Alarm, Control Panel, etc. The System can be activated by detectors automatically, and also by hand.


A water mist system is a fire protection system which uses very fine water sprays (i.e. water mist). The small water droplets allow the water mist to control, suppress or extinguish fires by:

  • Cooling both the flame and surrounding gases by evaporation
  • Displacing oxygen by evaporation
  • Attenuating radiant heat by the small droplets themselves


The effectiveness of a water mist system in fire suppression depends on its spray characteristics, which include the droplet size distribution, flux density

and spray dynamics, with respect to the fire scenario, such as the shielding of the fuel, fire size and ventilation conditions.
 

Advantages


1) Product Advantages
 
The use of water mist fire suppression, when compared to the use of gaseous agents and traditional sprinkler systems, has revealed advantages such as:
  • Immediate activation
  • High efficiency in the suppression of a wide variety of fires
  • Minimized water damage
  • Environmentally sound characteristics
  • No toxic problems

So really high pressure system, specialized tubing or piping that's used for that. Now, there are differences between water mist systems and the droplet sizes that they produce, so typically the smaller the water droplet size the better it is at extinguishing a hot fire. Larger droplets can work faster on lower temperature fires, but they all work for the systems that they're approved for or listed for.

Working Principle

Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room



Water Mist Fire System are generally used in conjunction with fire detectors, fire alarm fire extinguishing controllers, emergency start/stop buttons, sound and light alarms, deflation indicators and other fire fighting equipment. When a fire occurs in the protection area, the temperature and smoke detectors will send out a fire signal. After the logic analysis of the automatic fire alarm and extinguishing controller, it will send out a sound and light composite alarm signal, and at the same time send out a linkage command to turn off the linkage equipment. After a delay time, a fire extinguishing command is issued, the solenoid valve driver is opened, the container valve is opened, the fire extinguishing agent is released, and the fire is extinguished; if the duty officer discovers a fire, he can press the emergency start button outside the protective area door to implement the fire extinguishing operation ; There is also a manual button on the solenoid valve driver, and mechanical emergency manual operation can also be used to extinguish fire in an emergency.

 

Product Parameters

Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room

Pump Pressurized Type Water Mist Fire System

Code Number

Working Pressure

Flow(L/Min) Pump Speed(r/Min)  

  Dimension(mm) 

 Note

XSWBG112/14-PRI 

14MPa

112

1470

2200x1200x2000

One Work One Spare

XSWBG224/14-PRI

14MPa

224

1470

2650x1200x2000

Two Work One Spare

XSWBG336/14-PRI

14MPa

336

1470

2650x1200x2000 

Three Work One Spare

XSWBG448/14-PRI

14MPa

448

1470

3100x1200x2000 

Four Work One Spare

XSWBG560/14-PRI 

14MPa

560

1470

3100x1200x2000

Five Work One  Spare

XSWBG672/14-PRI

14MPa

672

1470

3550x1200x2000 

Six Work One  Spare

XSWBG784/14-PRI

14MPa

784

1470

3550x1200x2000 

Seven Work One Spare

 

Main Components

Electric motor of Highpressure water mist pumps
Our high-pressure water mist system adopts a three- phase asynchronous motor. Star buck start is used, and after 5 seconds of the start, it is transformed into a triangle start to achieve the purpose of reducing the start current at the moment of start and to
make the motor reach the rated power. The rated speed of the motor selected for the high- pressure water mist system should be consistent with the speed requirements of the pump.
Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room
MOTOR PUMPS
Model: FLHP80-PRI
Motor voltage: 380V
Material: Steel
Power: 30KW.
Max. pressure: 14 MPa
Max. flow: 112 L/min
Motor Speed: 1800 r/min
 Model: FLHP80
Material: Stainless Steel
Diameter of suction/discharge throat: DN40/DN32
Shaft diameter: Ø32mm
Connection flange diameter: Ø206mm
Motor Speed: 1470 RPM
Working: Q =112L/min, H = 140m
Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room

Pump control cabinet

Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room



The control cabinet of the high-pressure water mist pump unit is composed of star-delta controller, programmable controller, sensor, control circuit, and cabinet.
1. Voltage: AC 380V
2. Digital display screen can show pressure of pump outlet and liquid level of water tank
3. The working status indicator light can display the working status of each pump,
main and backup power supply, etc;
4. Adopting PLC control, stable and reliable, with strong anti-interference ability;
5. Equipped with a dual power switch, which can be connected to two power
sources to ensure reliable system use;
6. There are manual start and stop buttons on the control cabinet panel of the
pump unit, which can perform on-site start and stop operations on the pump
unit;
7. The pump control cabinet is equipped with emergency start and emergency
stop buttons, which can complete pump operation with one click.



Water Mist Nozzles
Open Type

Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room
Open Type
The open water mist nozzle is made of austenitic stainless steel and consists of a shell, a nozzle, etc. Its core component is a
plurality of centrifugal nozzles installed on the conical surface of the shell.

The atomization mechanism is to utilize the rotating liquid produced by the swirling parts in the nozzle to accelerate and eject
the hollow diffusion cone-shaped liquid film through the outlet channel, and use the speed difference between the liquid and the
outside air to break up and atomize.While on stand-by, our system boasts dry piping for maximum efficiency. Activation can be
achieved manually or through the sensors that detect heat, smoke, or flames - tailored to your specific needs.

Our nozzles are thoughtfully grouped in sections, so upon activation, all nozzles within the selected section will be released for
optimal fire suppression.

 

 

Code Number
Flow Rate(K)
Working Pressure(Mpa)
Working Flow(L/Min)
PRI/WM-N/T0.3/10
0.3
10.0-14.0
3.0-3.5
PRI/WM-N/T0.5/10
0.5
10.0-14.0
5.0-5.9
PRI/WM-N/T0.7/10
0.7
10.0-14.0
7.0-8.3
PRI/WM-N/T0.9/10
0.9
10.0-14.0
9.0-10.6
PRI/WM-N/T1.0/10
1.0
10.0-14.0
10.0-11.8
PRI/WM-N/T1.2/10
1.2
10.0-14.0
12.0-14.2
PRI/WM-N/T1.5/10
1.5
10.0-14.0
15.0-17.7
PRI/WM-N/T1.7/10
1.7
10.0-14.0
17.0-20.1
PRI/WM-N/T2.0/10
2.0
10.0-14.0
20.0-23.7
PRI/WM-N/T2.5/10
2.5
5.0-10.0
12.5-29.6
PRI/WM-N/T3.0/10
3.0
5.0-10.0
15.0-35.5
PRI/WM-N/T3.5/10
3.5
5.0-10.0
17.5-41.4
PRI/WM-N/T4.0/10
4.0
3.5-10.0
14.0-47.3
PRI/WM-N/T4.5/10
4.5
3.5-10.0
15.8-53.2
PRI/WM-N/T5.0/10
5.0
3.5-10.0
17.5-59.2
PRI/WM-N/T5.5/10
5.5
3.5-10.0
19.3-65.1

Close Type nozzle
 

The closed water mist nozzle is made of austenitic stainless steel and consists of a shell, a nozzle, a temperature-sensitive glass ball, etc. Its core component is a plurality of centrifugal nozzles installed on the conical surface of the shell. The atomization mechanism is to utilize the rotating liquid produced by the swirling parts in the nozzle to accelerate and eject the hollow diffusion cone-shaped liquid film through the outlet channel, and use the speed difference between the liquid and the outside air to break up and atomize.

While in standby mode, our system maintains a pipe pressure of approximately 12 bar. Once the temperature surpasses 57°C, the heat-sensitive glass bulbs integrated into the nozzle heads will begin to melt. As a result, the high-pressure pump will be automatically activated, forcing water through high-pressure nozzles (60 or 100 bar, depending on nozzle type) to produce a fine mist. Only those nozzles with melted bulbs will activate, ensuring that only the affected area is actively sprayed.
Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room
Code Number
Flow Rate(K)
Working Pressure(Mpa)
Working Flow(L/Min)
PRI/WM-N/T0.3/10-57ºC φ2
0.3
10.0-14.0
3.0-3.5
PRI/WM-N/T0.5/10-57ºC φ2
0.5
10.0-14.0
5.0-5.9
PRI/WM-N/T0.7/10-57ºC φ2
0.7
10.0-14.0
7.0-8.3
PRI/WM-N/T0.9/10-57ºC φ2
0.9
10.0-14.0
9.0-10.6
PRI/WM-N/T1.0/10-57ºC φ2
1.0
10.0-14.0
10.0-11.8
PRI/WM-N/T1.2/10-57ºC φ2
1.2
10.0-14.0
12.0-14.2
PRI/WM-N/T1.5/10-57ºC φ2
1.5
10.0-14.0
15.0-17.7
PRI/WM-N/T1.7/10-57ºC φ2
1.7
10.0-14.0
17.0-20.1
PRI/WM-N/T2.0/10-57ºC φ2
2.0
10.0-14.0
20.0-23.7
PRI/WM-N/T2.5/10-57ºC φ2
2.5
5.0-10.0
12.5-29.6
PRI/WM-N/T3.0/10-57ºC φ2
3.0
5.0-10.0
15.0-35.5
PRI/WM-N/T3.5/10-57ºC φ2
3.5
5.0-10.0
17.5-41.4
PRI/WM-N/T4.0/10-57ºC φ2
4.0
3.5-10.0
14.0-47.3
PRI/WM-N/T4.5/10-57ºC φ2
4.5
3.5-10.0
15.8-53.2
PRI/WM-N/T5.0/10-57ºC φ2
5.0
3.5-10.0
17.5-59.2
PRI/WM-N/T5.5/10-57ºC φ2
5.5
3.5-10.0
19.3-65.1

Details Pictures

 

Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room
Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room


 

Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room
Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room

 

Product Application

The fine water mist fire extinguishing system is widely used in various scenarios, including but not limited to
Computer Rooms, Data Centers, Archives, Libraries, Generator, Transformer, Electric Room
Engery Storage Container(Battery Room) Medical Device Room, Others Important Equipment Storage Places.
These places often store high-value equipment and materials, and once a fire occurs, the consequences can be unimaginable.
Therefore, using a fine water mist fire extinguishing system can quickly extinguish the fire source in the early stages of a fire and
protect important assets.High efficiency in the suppression of a wide variety of fires

Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room
1. Data centers and computer rooms: For data centers and computer rooms that store a large number of precision electronic devices, traditional fire extinguishing methods may cause damage to the equipment. The high-pressure fine water mist fire extinguishing system can not only quickly put out fires but also will not cause secondary damage to the equipment, ensuring data security and business continuity.
2. Transportation hubs: Airports, railway stations, subway stations and other transportation hubs have large Spaces and frequent personnel flow. This system can precisely extinguish fires in different zones, respond quickly to fire situations, and reduce the impact of fires on traffic order.
3. Cultural ancient buildings: When protecting ancient buildings, the high-pressure fine water mist fire extinguishing system, with its environmentally friendly and low-loss features, can effectively put out fires without damaging the original cultural relics, thus safeguarding historical and cultural heritages.
4. Industrial sites: Such as petrochemical, power, pharmaceutical and other industrial fields, in the face of complex environments with flammable, explosive and high temperatures, the system can provide protection for local key areas, effectively controlling the spread of fire.
 

Company Profile

 

Nfpa Pump Pressurized Type Water Mist Fire System for Medical Device Room

PRI-SAFETY was established in 2016, specializes in the design, 
manufacture of automatic fire suppression systems and advanced fire fighting equipment, national high-tech enterprise.
The main products are automatic fire suppression systems for vehicles and mechanical equipment, kitchen fire suppression system, FM200 / Novec1230 total flooding systems, water mist fire system, foam sprinkler mist fire systems, and mobile compressed air foam equipment. The products are used in mining, petrochemical,
transportation, electric power, industry, construction and other fields. Since 2005, PRI-SAFETY has been OEM various automatic fire extinguishing systems for engineering, vehicles and industrial equipment for European and American customers. After more than ten years of technology accumulation, it has formed perfect and reliable system products. At present, our products have been exported to more than 40 countries and regions.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier