The characteristics of electrical fire hazards are the distribution, persistence and concealment of fire hazards. Due to the wide distribution of electrical systems and long-term continuous operation, electrical lines are usually laid in concealed places (such as ceilings, cable trenches), and are not easy to be detected by the fire alarm system at the initial stage of a fire, nor are they easy to observe with the naked eye.
The danger of electrical fire is also closely related to the electricity consumption. When the electricity load increases, it is easy to cause electrical fires due to overcurrent. The casualties, property losses and social shocks caused by the fire are huge. Electrical fires mainly occur in buildings, where people are close, evacuation is difficult, and smoke is not smoothly exhausted. It is very easy to cause serious accidents of mass death and injury.
PRI-SAFETY electric equipment fire suppression systems have been specifically designed to protect electric equipment and put out electric fires caused by leakage electric (class E fire) quickly and
efficiently.
These self contained pneumatic systems require no external energy or power supply. Upon flame impingement or heat, the
pressurized detection tubing will burst and activate the cylinder valve to open and release the extinguishing agent.
PRI-SAFETY electric equipment fire suppression systems are specifically designed to extinguish fires of electric panel, battery bay, control panel, electric equipment etc. It is developed to prevent damage of equipment, records, people and other assets that are vital to a business.
Here are 2 types for Low Pressure Direct FM-200 Automatic Fire Suppression System,
one is Direct type activated by detection tube/emergency button and spray FM-200 extinguishing agent from the blasr hole in detection tube,
another is indirect type activated by detection tube/emergency button and spary FM-200 extinguishing agent from the nozzles in SS discharge pipe.
Direct Type Low Pressure Direct FM-200 Automatic Fire Suppression System:
Working Principle:
When there is a fire, and reach 140 degrees celsius, the tube will repture a hole, and the fire agent will discharge from this hole to extinguish fires within several seconds.
Items No. |
EFS-D01 |
EFS-D02 |
EFS-D03 |
EFS-D04 |
EFS-D06 |
Agent Capacity(kg) |
1kg |
2kg |
3kg |
4kg |
6kg |
Extinguishing Agent
|
HFC-227ea, HFC-263fa, FK-5112 |
Working Pressure (bar)
|
14bar |
14bar |
14bar |
14bar |
14bar |
Test Pressure(bar) |
27bar |
27bar |
27bar |
27bar |
27bar |
Cylinder Material
|
ST12 or SS304
|
ST12 or SS304
|
ST12 or SS304
|
ST12 or SS304
|
ST12 or SS304
|
Detection & Discharge
Pipe Tube
|
φ6mm
|
Activation Temperature
Detection Tube (ºC)
|
100ºC, 120ºC, 140ºC, 170ºC
|
Indirect Type of Low Pressure Direct FM-200 Automatic Fire Suppression System:
Working Principle:
When there is a fire, and reach 140 degrees celsius, the tube will repture a hole, then the pressure will release from the hole, and it will leads to activate the valve of the fire system to open, then the fire agent will discharge from discharge pipe to extinguish fires within several seconds
Items No. |
EFS-ID06 |
EFS-ID09 |
EFS-ID12 |
EFS-ID18 |
EFS-ID25 |
Agent Capacity(kg) |
6kg |
9kg |
12kg |
18kg |
25kg |
Extinguishing Agent
|
HFC-227ea, HFC-263fa, FK-5112 |
Working Pressure (bar)
|
14bar |
14bar |
14bar |
14bar |
14bar |
Test Pressure(bar) |
27bar |
27bar |
27bar |
27bar |
27bar |
Cylinder Material
|
ST12 or SS304
|
ST12 or SS304
|
ST12 or SS304
|
ST12 or SS304
|
ST12 or SS304
|
Detection & Discharge
Pipe Tube
|
φ6mm
|
Activation Temperature
Detection Tube (ºC)
|
100ºC, 120ºC, 140ºC, 170ºC
|
* Simple, high quality and well engineered system. Easy to install.
* Fast, automatic actuation.
* We use gas instead of water to put out the fire without causing damage.
* When a fire occurs, the system will first detect it and then feedback control the fire extinguishing system to turn on and extinguish the fire within 10 seconds.
* Remaining operational during power interruptio. u There is no need for manual close fire fighting.
1kg---For 1~1.25m³ Electric Panel
2kg---For 2~2.5m³ Electric Panel
6kg---For 6~7.5m³ Electric Panel
9kg---For 9~11.25m³ Electric Equipment
12kg--- For 12~15m³ Electric Room
20kg--- For 20~25m³ Electric Room
Bigger Capacity Could be Customized
* Electronic computer rooms
* Communication rooms
* Underground projects
* Offshore oil production platforms
* Libraries
* Archives
* Treasures warehouses
* Chemical combustibles warehouses
* Generator rooms
* Power distribution rooms
PRI-SAFETY specializes in the manufacture and exportation of Automatic Fire Systems, Throw Type Fire Extinguishers, CAFS Compressed Air Foam Fire Systems, Fire Extinguishers, Fire Hose Reels, Fire Hoses, Fire Cabinets, Valves, Pressure Gauges, Couplings, Smoke Alarms, Fire Blanket and other fire equipment, etc. We focus on providing one-stop fire-fighting products and professional service.
We have attained ISO9001:2000, CE, EN3, EN1869 and EN694 certifications. Almost all products that we provide are manufactured and tested according to the international standard. We also supply OEM service, we can design and produce the products as client's special request.
PRI-SAFETY also has very good after-sales service, we have one professional,high efficient and warmly sales team. We promise that all feedbacks from clients would be replied within 8 hours during working days. We always try our best to provide better service to meet our clients' demands.
Our company rule is saving time and cost for clients, taking good profit and well development for clients. We supply well growing space and training for each staff, help staffs to achieve their dreams. Then clients and staffs push our company development.
1. Who are we?
We are based in Zhejiang, China, start from 2009,sell to Western Europe(39.36%),Africa(15.12%),Mid East(15.04%),Central America(12.33%),South America(10.03%),North America(4.01%),Northern Europe(2.56%),Southeast Asia(1.05%),Eastern Asia(0.50%). There are total about 11-50 people in our office.
2. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
3. What can you buy from us?
Automatic Fire Suppression System,Tube fire system,CAFS Compressed Air Foam Fire System,Throwing Fire Extinguisher,Fire Extinguisher Accessoriers
4. Why should you buy from us not from other suppliers?
One Stop Fire Fighting Equipment supply and professional service. We have CE, EN3, EN671, EN1869 certificates. Mainly export to Europe, Middle east, South America, Africa,etc.
5. What services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF,EXW,Express Delivery;
Accepted Payment Currency:USD,CNY;
Accepted Payment Type: T/T,L/C,D/P D/A,Western Union,Cash;
Language Spoken:English,Chinese,Spanish