Customization: | Available |
---|---|
Agent: | Water Mist |
Type: | Pump Pressurised |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Description: |
How it works? |
1. Activation & Detection * Fire Detection: Sensors (smoke, heat, or flame detectors) identify a fire and trigger the system. * Control Panel Activation: The control unit activates the high-pressure pump and opens valves to direct water flow to the affected zone. 2. High-Pressure Water Generation * Pump Pressurization: A dedicated high-pressure pump (typically 70-200 bar or 1,000-3,000 psi) pressurizes water from a storage tank or mains supply. * Stable Pressure Maintenance: The pump ensures consistent pressure even as water is discharged, critical for effective mist generation. 3. Atomization at Nozzles * Nozzle Design: Specialized nozzles use high-pressure water flow to shear the water into micron-sized droplets (10-200 microns in diameter). * Mist Formation: The tiny droplets create a dense fog-like mist, vastly increasing the water's surface area compared to traditional sprinklers. |
4. Fire Suppression Mechanisms The fine mist achieves fire suppression through three key physical mechanisms: a) Rapid Cooling (Heat Absorption) * Evaporation: The large surface area of the droplets allows instant evaporation, absorbing heat energy from the fire. * This cools the flames and surrounding gases below the fire's ignition temperature. b) Oxygen Displacement * Steam Expansion: Evaporated water turns to steam, expanding up to 1,700 times in volume. * This dilutes oxygen levels in the fire zone.. c) Radiant Heat Blocking * Mist Curtain: The dense mist scatters and absorbs radiant heat, shielding unburned fuel and adjacent areas from ignition. 5. Post-Suppression Benefits * Minimal Water Damage: Limited water volume (often < 1 liter/min per nozzle) reduces collateral damage to assets. * Re-ignition Prevention: The cooling effect and residual mist inhibit re-flash of flammable materials. |
Technical Parameters |
Code No. | Working Pressure | Flow(L/Min) | Pump Speed(r/Min) | Dimensions(mm) | Note |
WM/PRI-112/14 | 14Mpa | 112 | 1470 | 2000x1200x2000 | 1 Work 1 Reserve |
WM/PRI-224/14 | 14Mpa | 224 | 1470 | 2650x1200x2000 | 2 Work 1 Reserve |
WM/PRI-336/14 | 14Mpa | 336 | 1470 | 2650x1200x2000 | 3 Work 1 Reserve |
WM/PRI-448/14 | 14Mpa | 448 | 1470 | 3100x1200x2000 | 4 Work 1 Reserve |
WM/PRI-560/14 | 14Mpa | 560 | 1470 | 3100x1200x2000 | 5 Work 1 Reserve |
WM/PRI-672/14 | 14Mpa | 672 | 1470 | 3550x1200x2000 | 6 Work 1 Reserve |
WM/PRI-784/14 | 14Mpa | 784 | 1470 | 3550x1200x2000 | 7 Work 1 Reserve |
Code No. | Working Pressure | Flow(L/Min) | Pump Speed(r/Min) | Dimensions(mm) | Note |
WM/PRI-134/16 | 16Mpa | 134 | 1470 | 2000x1200x2000 | 1 Work 1 Reserve |
WM/PRI-268/16 | 16Mpa | 268 | 1470 | 2650x1200x2000 | 2 Work 1 Reserve |
WM/PRI-402/16 | 16Mpa | 402 | 1470 | 2650x1200x2000 | 3 Work 1 Reserve |
WM/PRI-536/16 | 16Mpa | 536 | 1470 | 3100x1200x2000 | 4 Work 1 Reserve |
WM/PRI-670/16 | 16Mpa | 670 | 1470 | 3100x1200x2000 | 5 Work 1 Reserve |
WM/PRI-804/16 | 16Mpa | 804 | 1470 | 3550x1200x2000 | 6 Work 1 Reserve |
WM/PRI-938/16 | 16Mpa | 938 | 1470 | 3550x1200x2000 | 7 Work 1 Reserve |
Code No. | Working Pressure | Flow(L/Min) | Pump Speed(r/Min) | Dimensions(mm) | Note |
WM/PRI-168/16 | 13Mpa | 168 | 1470 | 2000x1200x2000 | 1 Work 1 Reserve |
WM/PRI-336/16 | 13Mpa | 336 | 1470 | 2650x1200x2000 | 2 Work 1 Reserve |
WM/PRI-504/16 | 13Mpa | 504 | 1470 | 2650x1200x2000 | 3 Work 1 Reserve |
WM/PRI-672/16 | 13Mpa | 672 | 1470 | 3100x1200x2000 | 4 Work 1 Reserve |
WM/PRI-840/16 | 13Mpa | 840 | 1470 | 3100x1200x2000 | 5 Work 1 Reserve |
WM/PRI-1008/16 | 13Mpa | 1008 | 1470 | 3550x1200x2000 | 6 Work 1 Reserve |
WM/PRI-1176/16 | 13Mpa | 1176 | 1470 | 3550x1200x2000 | 7 Work 1 Reserve |
Code Number | Flow Rate(K) | Working Pressure(Mpa) | WorkingFlow(L/Min) |
PRI/WM-N/T0.3/10-57ºC φ2 | 0.3 | 10.0-14.0 | 3.0-3.5 |
PRI/WM-N/T0.5/10-57ºC φ2 | 0.5 | 10.0-14.0 | 5.0-5.9 |
PRI/WM-N/T0.7/10-57ºC φ2 | 0.7 | 10.0-14.0 | 7.0-8.3 |
PRI/WM-N/T0.9/10-57ºC φ2 | 0.9 | 10.0-14.0 | 9.0-10.6 |
PRI/WM-N/T1.0/10-57ºC φ2 | 1.0 | 10.0-14.0 | 10.0-11.8 |
PRI/WM-N/T1.2/10-57ºC φ2 | 1.2 | 10.0-14.0 | 12.0-14.2 |
PRI/WM-N/T1.5/10-57ºC φ2 | 1.5 | 10.0-14.0 | 15.0-17.7 |
PRI/WM-N/T1.7/10-57ºC φ2 | 1.7 | 10.0-14.0 | 17.0-20.1 |
PRI/WM-N/T2.0/10-57ºC φ2 | 2.0 | 10.0-14.0 | 20.0-23.7 |
PRI/WM-N/T2.5/10-57ºC φ2 | 2.5 | 5.0-10.0 | 12.5-29.6 |
PRI/WM-N/T3.0/10-57ºC φ2 | 3.0 | 5.0-10.0 | 15.0-35.5 |
PRI/WM-N/T3.5/10-57ºC φ2 | 3.5 | 5.0-10.0 | 17.5-41.4 |
PRI/WM-N/T4.0/10-57ºC φ2 | 4.0 | 3.5-10.0 | 14.0-47.3 |
PRI/WM-N/T4.5/10-57ºC φ2 | 4.5 | 3.5-10.0 | 15.8-53.2 |
PRI/WM-N/T5.0/10-57ºC φ2 | 5.0 | 3.5-10.0 | 17.5-59.2 |
PRI/WM-N/T5.5/10-57ºC φ2 | 5.5 | 3.5-10.0 | 19.3-65.1 |
Code Number | Flow Rate(K) | Working Pressure(Mpa) | WorkingFlow(L/Min) |
PRI/WM-N/T0.3/10 | 0.3 | 10.0-14.0 | 3.0-3.5 |
PRI/WM-N/T0.5/10 | 0.5 | 10.0-14.0 | 5.0-5.9 |
PRI/WM-N/T0.7/10 | 0.7 | 10.0-14.0 | 7.0-8.3 |
PRI/WM-N/T0.9/10 | 0.9 | 10.0-14.0 | 9.0-10.6 |
PRI/WM-N/T1.0/10 | 1.0 | 10.0-14.0 | 10.0-11.8 |
PRI/WM-N/T1.2/10 | 1.2 | 10.0-14.0 | 12.0-14.2 |
PRI/WM-N/T1.5/10 | 1.5 | 10.0-14.0 | 15.0-17.7 |
PRI/WM-N/T1.7/10 | 1.7 | 10.0-14.0 | 17.0-20.1 |
PRI/WM-N/T2.0/10 | 2.0 | 10.0-14.0 | 20.0-23.7 |
PRI/WM-N/T2.5/10 | 2.5 | 5.0-10.0 | 12.5-29.6 |
PRI/WM-N/T3.0/10 | 3.0 | 5.0-10.0 | 15.0-35.5 |
PRI/WM-N/T3.5/10 | 3.5 | 5.0-10.0 | 17.5-41.4 |
PRI/WM-N/T4.0/10 | 4.0 | 3.5-10.0 | 14.0-47.3 |
PRI/WM-N/T4.5/10 | 4.5 | 3.5-10.0 | 15.8-53.2 |
PRI/WM-N/T5.0/10 | 5.0 | 3.5-10.0 | 17.5-59.2 |
PRI/WM-N/T5.5/10 | 5.5 | 3.5-10.0 | 19.3-65.1 |
System Components: |
Packing & Delivery |
Product Applications: |
1. Commercial Settings Data Centers: Protects sensitive electronics with minimal water damage. Hospitals: Ensures fire suppression without disrupting medical equipment or patient safety. Museums/Libraries: Safeguards artifacts and books by minimizing water exposure. Shopping Malls/Office Buildings: Efficiently controls fires while reducing collateral damage. |
2. Industrial Environments Oil & Gas Facilities: Suppresses flammable liquid/gas fires without spreading hazards. Power Plants: Protects turbines and generators; effective in controlling high-heat fires. Manufacturing Plants: Ideal for machinery spaces with overheating risks. Pharmaceutical Clean Rooms: Prevents contamination while suppressing fires. |
3. Transportation Marine Vessels: Uses seawater in confined spaces (engine rooms, cargo holds). Aircraft Hangars: Safeguards expensive equipment and complies with aviation safety standards. Tunnels: Functions effectively in ventilated or underground environments. Rail/Public Transit: Deployed in stations or trains for rapid response. |
Project installation example |