PRI-SAFETY Self-Activated system
is specially designed used for electrical engineering rooms, electrical Panels , a small area where is not suitable with automatic fire extinguishing system by water, by powder and foaming solution. Fire extinguishing agent is contained in gas cylinder in the form of liquefied gas and compressed with nitrogen to pressure 25 bar.
Capacity and Filling Weight
|
Tank Volume |
Code Number |
HFC-227ea Filling Weight |
Working Pressure |
Activated Temperature |
Discharge Time |
8L |
FK-SA08/2.5-PR |
4kg~8kg
|
25Bar |
68ºC |
≤8s |
12L |
FK-SA12/2.5-PR |
6kg~12kg
|
25Bar |
68ºC |
≤8s |
15L |
FK-SA15/2.5-PR |
10kg~15kg |
25Bar |
68ºC |
≤8s |
16L |
FK-SA16/2.5-PR |
10kg~16kg |
25Bar |
68ºC |
≤8s |
25L |
FK-SA25/2.5-PR |
16kg~25kg |
25Bar |
68ºC |
≤8s |
Gas cylinder head valve uses fast-response glass bulb-type trigger with 68'ºC impact temperature. The thermo-sensor glass is attached with a valve structure that provides 360-degree impact protection.The system can use l stand-alone bottle for a zone or allow connection of up to 5 cylinders when equipping area with large volume.
When using gas cylinders connected together, when any cylinder in the cylinder assembly is activated by inductor the thermostat, the gas cylinders connected to the tank assembly will be stimulated simultaneously by pressure through the DN6 copper pipe, ensure that the amount of extinguishant in all cylinders is discharged within 10 seconds according to regulations. The 180 degree gas discharge nozzle, with a 5m protection distance attached to the tank head valve, will discharge extinguishant when the tank gas is activated.
Installation Method 1:
H<=4.5m Fix on the wall, Distance to Roof 100~400mm.
Installation Method 2:
H>4.5m Fix on the wall, 2 layer installation.
Installation Method 3:
Protection radius:R=5m. The maximum distance between pots:L= 6m
The PRI-SAFETY Self-Activated HFC-227ea Automatic Fire Suppression System is designed for environments where traditional fire suppression methods, such as water, powder, or foam, are unsuitable due to the risk of damaging sensitive equipment or causing operational disruption. Given its clean agent properties and automatic activation, this system is particularly suited for the following applications:
1. Electrical Engineering Rooms Application: Protects electrical engineering rooms that house critical electrical infrastructure. These rooms often contain sensitive equipment and high-voltage components, making traditional suppression methods potentially hazardous.
2. Electrical Panels and Cabinets Application: Ideal for protecting electrical panels, switchgear, and control cabinets where fires can start due to short circuits, overheating, or electrical faults.
3. Server Rooms and Data Centers Application: Protects server rooms, data centers, and communication hubs where sensitive electronic equipment requires a clean, residue-free fire suppression solution.
4. Telecommunication Facilities Application: Suitable for use in telecom facilities where equipment is highly sensitive and requires protection from both fire and the damaging effects of water or other suppression agents.
5. Control Rooms Application: Used in control rooms that monitor industrial processes, power plants, or critical infrastructure, where fire can lead to significant operational hazards.
6. Medical Facilities (e.g., MRI Rooms) Application: Appropriate for protecting areas with sensitive medical equipment, such as MRI machines or other imaging devices, where water or powder could cause irreparable damage.
7. Museums, Archives, and Libraries Application: Suitable for protecting valuable collections, rare documents, and artifacts where traditional fire suppression methods could cause irreversible damage.
8. Transportation (e.g., Marine Vessels) Application: Used in confined spaces on marine vessels, such as engine rooms or control rooms, where space is limited and rapid fire suppression is critical.
9. Energy Sector (e.g., Transformer Rooms) Application: Protects transformer rooms and substations where fires can result from electrical faults, posing a significant risk to energy supply.
10. Small, Enclosed Areas Application: Any small, enclosed space where the use of water, powder, or foam-based systems is impractical or potentially damaging. Summary The PRI-SAFETY Self-Activated HFC-227ea Automatic Fire Suppression System is particularly well-suited for applications where clean, effective, and rapid fire suppression is required, and where traditional methods might cause damage or be ineffective. Its versatility makes it ideal for a wide range of environments, particularly those involving sensitive or valuable equipment.
1. who are we?
We are based in Zhejiang, China, start from 2009,sell to South America(25.00%),North America(15.00%),Southeast Asia(15.00%),Mid East(12.00%),Africa(7.00%),Eastern Europe(5.00%),South Asia(3.00%),Eastern Asia(3.00%),Oceania(3.00%),Western Europe(3.00%),Southern Europe(3.00%),Central America(3.00%),Northern Europe(2.00%),Domestic Market(1.00%). There are total about 11-50 people in our office.
2. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
3.what can you buy from us?
FM200 Fire Systems; Vehicle Automatic Fire Systems; Kitchen Automatic Fire Systems; CAFS Fire Systems; Automatic Fire Tube
4. why should you buy from us not from other suppliers?
One Stop Fire Fighting Equipment supply and professional service. We have CE, EN3, EN671, EN1869 certificates. Mainly export to Europe, Middle east, South America, Africa,etc.
5. what services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF,EXW,Express Delivery;
Accepted Payment Currency:USD,CNY;
Accepted Payment Type: T/T,L/C,D/P D/A,Western Union,Cash;
Language Spoken:English,Chinese,Spanish