The HFC227ea / FM200 total flooding fire suppression system offers fast and residue-free extinguishment of fires in critical environments. Utilizing a clean agent that evaporates quickly upon discharge, it effectively extinguishes fires without leaving residue, making it ideal for sensitive areas like data centers, control rooms, and museums. This system reacts swiftly to suppress fires, minimizing damage and downtime while ensuring the safety of personnel and assets. FM200 is environmentally sustainable with a low global warming potential and zero ozone depletion potential, aligning with strict regulatory standards. Its versatile design allows for easy installation and integration with existing fire detection systems, providing reliable fire protection tailored to specific spatial requirements. With its rapid response and minimal environmental impact, the FM200 system stands as a state-of-the-art solution for protecting valuable assets and maintaining operational continuity in critical infrastructures.
Product Advantage
Easy Operate: Convenient and easy to operate
CCC Authentication: Quality assurance,safety genuine
Alarm system: Real-time detection, alert alerts
Automatic: Fire extinguishing automatically to reduce losses
Not conductive: Safety agent to pro-tect the machine
Environmentally: Green is easy to clean, no residue
Innocuity: Safe medicine, no poison harmless
Fast Fire Extinguishing: Fire extinguishing quickly reduces damage
High Quality: SUS304 stainless steel material cylinder
At moment, we have two different Activation Modes.
I. Pilot Cylinder Activation Mode
The Pilot Cylinder total flooding FM200 fire system operates as follows.
-
Fire Suppression Process:
- Detection and Activation: Upon fire detection, the system initiates the activation sequence.
- Pilot Cylinder Activation: The pilot cylinder is activated either automatically upon detection or manually triggered. Activation of the pilot cylinder releases the pressurized gas or liquid stored within it.
- Valve Operation: The release of pressure from the pilot cylinder operates valves within the system.
- Solenoid Valve Opening: The pilot cylinder's operation triggers the opening of the main solenoid valve or valves that control the flow of FM200 from the storage containers.
- Agent Discharge: FM200 is discharged through the distribution piping into the protected area. It quickly fills the space as a gas, displacing oxygen and effectively extinguishing the fire by cooling and interrupting the combustion process.
-
Advantages:
- Fast Response: The pilot cylinder system offers rapid deployment of FM200 upon activation, ensuring swift suppression of fires.
- Reliability: It combines automatic detection with a robust mechanical activation mechanism, enhancing system reliability.
- Effective Coverage: Ensures comprehensive coverage of the protected area due to the controlled release of the fire suppression agent.
II. Solenoid valve Activation Mode
The solenoid valve total flooding FM200 fire system operates as follows.
- Fire Suppression Process:
- Fire Detection: Upon detection of a fire by the smoke alarm or temperature alarm, a signal is sent to the fire suppression system.
- Signal Transmission: The signal is relayed to the control system which activates the solenoid valve.
- Solenoid Valve Actuation: Upon receiving the signal, the solenoid valve opens, allowing FM200 to discharge from the storage container into the protected area through the piping network.
- Extinguishing Action: FM200 rapidly fills the protected area as a harmless gas, effectively extinguishing or controlling the fire.
-
Features and Advantages:
- Fast Fire Suppression: FM200 has a very short atmospheric lifetime, enabling quick suppression of flames at the onset of a fire.
- Environmental Compatibility: The agent does not deplete the ozone layer and has minimal impact on the environment.
- Safety: Compared to traditional gas-based systems, FM200 offers enhanced safety for occupants as it poses no harm at design concentrations.
1. Cylinders Paremeters
Item |
Specification |
Capacity
|
32L 70L 90L 120L 150L 180L 250L 345L 450L 500L, support OEM capacity |
Material of Cylinder |
SUS304 stainless steel |
Spray Time |
≤10s |
Power |
DC24V/1.6A |
Max Working Pressure |
4.2MPa, 5.6MPa, 8.0MPa. |
Thread Size |
≤70Lcylinder:PZ56/2-8UN.2A
≤90L Cylinder: PZ56/3-1/4"-8UN.2A
≤150L Cylinder: M64×2/3-1/4"-8UN.2A
≥180L Cylinder: M80×2/3-1/4"-8UN.2A |
2. High Quality Head Valve Paremeters
Code NO. |
AV25/4.2-PRI |
AV50/4.2-PRI |
AV25/5.3-PRI |
AV50/5.3-PRI |
Size |
G 1" |
G 2" |
Nech Thread |
2-8UN.2A |
3 1/4-8UN.2A |
Actuator Thread |
G 1" |
G 2" |
High Pressure
Flexible Hose Thread |
G 1" |
G 2" |
Pressure Guage Thread |
1/8" NPT |
1/8" NPT |
Working Pressure |
6.7MPa |
Testing Pressure |
10.05MPa |
Application Cylinder |
<70L |
70L 90L 120L 150L 180L |
3. High Quality Pneumatic and Soleniod Valve Paremeters
Pneumatic Valve (High Quality Model) |
Code NO. |
APV-PRI |
Thread |
G 1" |
Working Pressure |
6.6MPa |
Solenoid Valve (Hight Quality Model) |
Code NO. |
ASV90N-PRI |
Thread |
G 1" |
Power |
DC 24V |
Drive Force |
90N |
4. Gas Check Valve and Pressure Switch
Gas Check Valve |
Code NO. |
GCV6/6.6-PRI |
Inlet/Outlet |
M14*1.5 |
Open Force |
0.2MPa |
Working Pressure |
6.6MPa |
Material |
HPb59-1 |
Pressure Switch |
Code NO. |
PS0.8/5.3-PRI |
Operating Pressure |
0.8MPa±0.08MPa |
Thread |
RC 1/2" |
Material |
HPb59-1 |
5. Normal Pressure Gauge Paremeters
Code NO. |
PG/2.5-PRI |
PG/4.2-PRI |
PG/5.3-PRI |
PG/6.6-PRI |
Working Pressure |
2.5MPa |
4.2MPa |
5.3MPa |
6.6MPa |
Thread |
M10x1 |
6. High Quality Pressure Gauge Paremeters
Code NO. |
PG/2.5-PRI |
PG/4.2-PRI |
PG/5.3-PRI |
Working Pressure |
2.5MPa |
4.2MPa |
5.3MPa |
Thread |
1/8' NPT |
7. Flexible Hose With Elbow Paremeters
Flexible Hose With Elbow |
Size |
DN32 |
DN40 |
DN50 |
Code NO. |
FHE/32-PRI |
FHE/40-PRI |
FHE/50-PRI |
Thread |
M48x2 |
M56x2 |
M68x2 |
Material |
Brass (HPb59-1) |
Length |
700mm |
8. Flexible Hose Without Elbow Paremeters
Flexible Hose Without Elbow |
Size |
DN32 |
DN40 |
DN50 |
Code NO. |
FH/32-PRI |
FH/40-PRI |
FH/50-PRI |
Thread |
M48x2 |
M56x2 |
M68x2 |
Material |
Brass (HPb59-1) |
Length |
500mm |
9. Fire Alarm System
I. Single Bottle With Pilot Bottle or With Solenoid Valve
II. Multiple Bottle With Pilot Bottle or With Solenoid Valve
III. Multi-Room Distribution System with Pilot Bottle
---the end---