Fk-5112 Fire Suppression System

Still deciding? Get samples of $ !
Order Sample
Product Details
Customization: Available
Agent: Novec1230 Fk-5112 FM200 Hfc 227ea
Type: Transportable Fire Extinguisher
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2016-11-04
Number of Employees
18
  • Fk-5112 Fire Suppression System
  • Fk-5112 Fire Suppression System
  • Fk-5112 Fire Suppression System
  • Fk-5112 Fire Suppression System
  • Fk-5112 Fire Suppression System
  • Fk-5112 Fire Suppression System
Find Similar Products
  • Overview
  • Product Overview
  • Application
  • Packing & Shipping
Overview

Basic Info.

Object
Class E Fires
Size
1~50kg
Certification
CE, UL
Portable Extinguisher
Novec1230 Fk-5112 FM200 Hfc 227ea
Effective Range
9m
Retirement Life
8 Years
Dry Powder Type
Novec1230 Fk-5112 FM200 Hfc 227ea
Power Source
Gas Fire Extinguisher
Product Name
Novec1230 FM200 Automatic Fire System
Activation Type
Direct & Indirect Activation Systems
Extinguishing Agent
Novec1230 Fk-5112 FM200 Hfc 227ea
Capacity Range
1kg to 50kg
Test Pressure
27bar
Working Pressure
14 Bar
Cylinder Material
St12 or SUS304
Activation Temperature
100°C, 120°C, 140°C, 170°C (Customizable)
Protection Volume
1m³ to 62.5m³ (Customizable)
Detection Tube Diameter
φ6mm
Discharge Pipe
φ16mm / φ20mm SUS304 (Indirect Type)
Application
Electric Panels, Electrical Cabine, etc
Certifications
ISO9001:2015, CE, UL
Factory or Trading
Factory
Payment Prefer
Tt
Transport Package
Carton Box or Wooden Box
Specification
1~50kg
Trademark
PRI-SAFETY
Origin
China
HS Code
84241000
Production Capacity
10000PCS/Month

Packaging & Delivery

Package Size
11.00cm * 11.00cm * 15.00cm
Package Gross Weight
5.000kg

Product Description

Product Overview
Fk-5112 Fire Suppression System
Fk-5112 Fire Suppression System
Fk-5112 Fire Suppression System

The PRI-SAFETY Electric Panel Automatic Fire Suppression System is an innovative, self-contained fire protection solution designed specifically for electrical equipment and E-class fires. Utilizing a pneumatic detection tube that bursts upon contact with heat or flame, the system activates instantly without the need for external power or human intervention.
 
Ideal for use in electric panels, control cabinets, battery compartments, and electrical rooms, this system releases a clean gas extinguishing agent (HFC-227ea/FM200, or Novec1230/FK-5112) to suppress fires within seconds, minimizing damage to critical assets and ensuring operational continuity.
 
Available in both Direct and Indirect types, with capacities from 1KG to 50KG, the system can be customized to fit various protection volumes and temperature requirements. It is engineered for easy installation, reliability, and compliance with international safety standards.
Fk-5112 Fire Suppression System
1.  Direct Type automatic fire suppression systems
In the Direct Type system, the pressurized detection tube is also the discharge tube. It is routed directly through the protected risk area (e.g., inside an electric panel). When fire impinges on any point of the tube, it bursts at that point, causing a pressure drop that activates the cylinder valve. The extinguishing agent is then released directly through the same burst tube, targeting the fire at its source.
 
Direct Type System Workflow:
1. Detection & Activation: The red, pressurized detection tube (φ6mm) is installed directly within the protected compartment (e.g., an electric panel). When a fire starts, the heat causes the tube to burst at the hottest point. The sudden loss of pressure inside the tube is the triggering mechanism.
2. Agent Release: This pressure drop instantly activates the valve on the extinguisher cylinder. The extinguishing agent is released directly through the burst section of the same tube, applying the agent precisely at the source of the fire.
3. Fire Suppression & Alarm (Optional): The clean agent (HFC-227ea/FK-5112) floods the enclosed space, suppressing the fire within seconds without damaging sensitive electronic equipment.The system can be integrated with an optional fire alarm panel to provide remote notification.
Key Components:
Ideal For: Compact enclosed spaces such as:
*Cylinder (1KG to 9KG capacity)
*Pressurized Detection/Discharge Tube (φ6mm)
*Mounting Bracket
*No External Power or Control Unit Required
*Individual Electric Control Panels
*CNC Machine Electrical Cabinets
*UPS and Battery Enclosures
*Server Racks
Item No.
EFS-D01
EFS-D02
EFS-D03
EFS-D04
EFS-D06
EFS-D09
Capacity(KG)
1KG
2KG
3KG
4KG
6KG
9KG
Fire Agent
HFC-227ea/FM200, or Novec1230/FK-5112
Working Pressure
14BAR
Test Pressure
27BAR
Cylinder Material
ST12 or SS304
Detection Tube Diameter
φ6mm
Activation Temperature
100℃, 120℃, 140℃, 170℃
Protection Volume
1~1.25m3
2~2.5m³
3~3.75m³
4~5m³
6~7.5m³
9~11.
Discharges Time
≤10s
Cylinder material
Steel (red painted) or Stainless Steel 304
Fk-5112 Fire Suppression System
2.  Indirect Type automatic fire suppression systems
The Indirect Type system separates the detection line from the discharge network. A small-diameter detection tube (φ6mm) is routed through the risk area. When it bursts due to heat, it triggers a pilot valve on the main cylinder. The extinguishing agent is then released through a separate discharge pipe (φ16mm or φ20mm SUS304) and directed via nozzles strategically placed in the protected zone.
 
Indirect Type System Workflow:
1. Detection: The separate, dedicated detection tube (φ6mm) is snaked through the entire risk area (e.g., an entire battery room or multiple cabinets). Upon exposure to heat, it bursts at the point of origin.
2. Valve Triggering: The pressure drop in the detection tube acts on a pilot valve on the main agent cylinder, causing it to open.
3. Discharge: The extinguishing agent is released through a separate, robust discharge pipe network (φ16mm/20mm SUS304) and is distributed through strategically placed nozzles. This ensures even and complete coverage of the entire protected volume.
4. Fire Suppression & Alarm (Optional): The agent is discharged uniformly, rapidly suppressing the fire. The system can be integrated with an optional fire alarm panel to provide remote notification.
Key Components:
Ideal For: Larger or multi-compartment spaces such as:
*Cylinder (6KG to 50KG capacity)
*Separate Detection Tube (φ6mm) & Discharge Pipe (φ16mm/φ20mm)
*Nozzles for Directed Agent Release
*Optional Fire Alarm and Manual Actuation
*Steel Mounting Bracket
*Electric Control Rooms
*Battery Storage Rooms
*Power Distribution Cabinets
*Switch Rooms and Larger Enclosures
Item No.
EFS-ID06
EFS-ID09
EFS-ID12
EFS-ID18
EFS-ID25
EFS-ID50
Capacity(KG)
6KG
9KG
12KG
18KG
25KG
50KG
Fire Agent
HFC-227ea/FM200, or Novec1230/FK-5112
Working Pressure
14BAR
Test Pressure
27BAR
Cylinder Material
ST12 or SS304
Detection Tube Diameter
φ6mm
Activation Temperature
100℃, 120℃, 140℃, 170℃
Protection Volume
6~7.5m3
9~11.25m³
12~15m³
18~22.5m³
25~31.25m³
50~62.5m³
Fk-5112 Fire Suppression System
Fk-5112 Fire Suppression System
               Direct                    VS                       Indirect
Feature
Direct Type System
Indirect Type System
Principle
Detection tubeisthe discharge tube
Separatedetection tube and discharge pipe
Best For
Single, sealed enclosures
Larger volumes, multiple compartments, complex layouts
Coverage
Localized, point-of-origin suppression
Widespread, total flooding application
Installation
Very simple, minimal components
More complex, requires nozzle placement & pipe routing
Cost-Effectiveness
Highly cost-effective for single units
Ideal for larger, centralized protection
Agent Delivery
Directly through burst hole in tube
Through dedicated nozzles for even distribution
How to Choose the Right System?
Choose DIRECT TYPE if:
You need a simple, self-contained system for a single, compact enclosure where the fire risk is localized.
Choose INDIRECT TYPE if:
You are protecting a larger room or multiple compartments, and need a centralized cylinder with distributed nozzles for full coverage.
Application
Fk-5112 Fire Suppression System
Applications in Detail:

Where to Install Direct Type Systems:
*CNC Machine Electrical Cabinets
*Wind Turbine Convertor Cabinets
*Telecom Shelter Control Panels
*UPS/Inverter Enclosures
*Industrial Robot Control Boxes

Where to Install Indirect Type Systems:
*Electric Vehicle Charging Stations
*Battery Energy Storage Systems (BESS)
*Power Distribution Rooms
*Marine Engine Control Rooms
*Generator Set Enclosures
*Data Server Rooms
Fk-5112 Fire Suppression System
Packing & Shipping
Fk-5112 Fire Suppression System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now