FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms

Product Details
Customization: Available
Agent: Hfc-227ea/ FM200 Gas
Type: Pre-Engineered
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 2 R&D engineers, you can check the Audit Report for more information
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
Fire Protection Product Certification
to see all verified strength labels (23)
  • FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms
  • FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms
  • FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms
  • FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms
  • FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms
  • FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • How it works
  • Product Configuration
  • Installation Example
  • Packing & Delivery
  • Company Profile
Overview

Basic Info.

Model NO.
QMQ5.6/150N-PRI
Object
Class a, B, C and E Fires
Size
16/32/40/70/82.5/90/100/120/140/150/250/345/350L
Certification
CCC, ISO 9001
Portable Extinguisher
Pre-Engineered
Effective Range
Depends on System Capacity
Retirement Life
8 Years
Dry Powder Type
Hfc-227ea/ FM200 Gas
Power Source
Pressure Fire Extinguisher
OEM
Support
ODM
Support
Filling Pressure
4.2/5.6MPa
Scale of Protective Region for One Zone
Area: Max Single-Zone Is 800m²
Spraying Time
≤10s
Filling Density
≤950kg/M3/ ≤1080kg/M3
Power
DC24V/1.6A
Nitrogen Pressure of Driving Device
6.0±1.0MPa(20℃)
Condition of Reserving Room for Containe
Temperature: -10~50℃, Relative Humidity: ≤97%
Max Working Pressure
5.3MPa/8.0MPa
Min Working Pressure
4.2MPa/5.6MPa
Certificate
UL Listed Hfc-227ea
Cylinder Material
Steel/ SUS304
Transport Package
High Quality Export Packing
Specification
16/32/40/70/82.5/90/100/120/140/150/250/345/350L
Trademark
PRI-SAFETY
Origin
China
HS Code
842410
Production Capacity
3000sets/Month

Packaging & Delivery

Package Size
65.00cm * 65.00cm * 185.00cm
Package Gross Weight
195.000kg

Product Description

FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms

PRI-SAFETY is a one-stop FM-200(HFC-227ea) fire suppression system provider, offering end-to-end services including:
1. System design & calculation (room volume, nozzle layout, pipe sizing)
2. Manufacturing & factory testing of FM-200 systems and components
3. International shipping & export support
4. Installation guidance & technical support on site
5. System commissioning & debugging
6. After-sales inspection, maintenance, and technical service
From concept to long-term operation, PRI-SAFETY ensures reliable and compliant fire protection.
Product Description
FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms

HFC-227ea Total Flooding System is a sophisticated, fast-acting, and clean fire suppression solution engineered for one purpose: to stop a fire instantly in a critical environment without causing the collateral damage that would defeat the purpose of protecting the asset in the first place.
We need it because in our modern, technology-dependent world, the value of the data and equipment, and the cost of downtime, far exceed the cost of installing and maintaining such a specialized protection system. It is the insurance policy that allows you to recover from a fire event, not just survive it.

It is a fixed, engineered fire suppression system designed to rapidly detect and extinguish fires in enclosed, mission-critical spaces by flooding the entire protected volume with HFC-227ea gas (chemical name: heptafluoropropane, commonly known by its brand name FM-200™).
FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms
FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms
Specification
Item
Description
Technical Parameter
1
Filling pressure
4.2Mpa
5.6Mpa
2
Scale of Protective region for one zone
Area:max single-zone is 800m² volume:max single-zone is 3600m³
3
Spraying time
≤10s
4
Filling density
≤950kg/m3
≤1080kg/m3
5
Power
DC24V/1.6A
6
Nitrogen Pressure of Driving Device
6.0±1.0Mpa(20℃)
7
Condition of reserving room for container
Temperature: -10~50℃, relative humidity: ≤97%
8
Max working pressure
5.3Mpa
8.0Mpa
9
Min working pressure
4.2Mpa
5.6Mpa
10
Capacity
16/32/40/70/82.5/90/100/120/140/150/250/345/350L
FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms
FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms
FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms
Agent Instruction
HFC-227ea fire suppression agent is an optimal substitute for Halon 1301. lt is particularly useful in computer rooms, libraries, semiconductor manufacturing facilities, data processing centers, industrial process control rooms, petrochemical facilities, chemical storage rooms and so on.
 
Features:
* An environmentally substitute for Halon 1301 with zero ODP. 
* Safe for people and animal. 
* Clean and do not leave residue. 
* Electrically nonconductive and noncorrosive. 
* UL Recognized and FM Approved.
How it works
FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms

How Does the FM-200 (HFC-227ea) Total Flooding Fire System Work?
1. Detection: The system's smoke detectors sense a fire in its incipient stage.
2. Alarm & Delay: The control panel activates audible/visual pre-discharge alarms inside and outside the room. A typical 30-second delay begins to allow for evacuation and manual intervention.
3. Discharge: At the end of the delay, the system electrically activates the cylinder valves. The HFC-227ea is propelled through the pipe network and discharged from the nozzles as a vapor.
4. Extinguishment: The agent floods the room, achieving the design concentration (usually 7-9%) within 10 seconds or less, rapidly suppressing the fire.
5. Safety: After discharge, the agent is safe for people to breathe at typical exposure levels (it has a high NOAEL - No Observed Adverse Effect Level) and simply ventilates away, leaving no damage to sensitive equipment.
FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms
In Summary:
An FM-200 total flooding fire system works by detecting a fire early and rapidly releasing a clean gaseous agent into an enclosed space, extinguishing the fire before it can grow or spread—all without damaging equipment.
Product Configuration
FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms

FM200 Cylinder Specification---4.2MPa 
Working Pressure: 4.2MPa Test Pressure: 6.3MPa Burst Pressure>13.90MPa 
HFC-227ea Agent Filling Rate ≤1.15
Item
Code No.
Capacity
Thread
Inner Dia.(mm)
Height(mm)
Wall Thickness(mm)
Weight(kg)
Max. Working Pressure
1
C16/4.2-PRI
16L
PZ56/2-8UN.2A
300
408
4
16
4.2
2
C32/4.2-PRI
32L
PZ56/2-8UN.2A
300
634
4
28
4.2
3
C40/4.2-PRI
40L
PZ56/2-8UN.2A
300
747
4
30
4.2
4
C70/4.2-PRI
70L
PZ56/2-8UN.2A
350
926
4.5
42
4.2
5
C82.5/4.2-PRI
82.5L
PZ56/3-1/4"-8UN.2A
350
1050
4.5
47
4.2
6
C90/4.2-PRI
90L
PZ56/3-1/4"-8UN.2A
350
1125
4.5
51.5
4.2
7
C100/4.2-PRI
100L
PZ56/3-1/4"-8UN.2A
350
1225
4.5
54
4.2
8
C105/4.2-PRI
105L
PZ56/3-1/4"-8UN.2A
350
1295
4.5
55.5
4.2
9
C120/4.2-PRI
120L
M64x2/3-1/4"-8UN.2A
350
1430
4.5
62.5
4.2
10
C140/4.2-PRI
140L
M64x2/3-1/4"-8UN.2A
400
1315
5
74.5
4.2
11
C150/4.2-PRI
150L
M64x2/3-1/4"-8UN.2A
400
1395
5
77
4.2
12
C180/4.2-PRI
180L
M80x2/3-1/4"-8UN.2A
400
1635
5.5
101
4.2
13
C250/4.2-PRI
250L
M80x2/3-1/4"-8UN.2A
500
1500
8
180
4.2
14
C345/4.2-PRI
345L
M80x2/3-1/4"-8UN.2A
600
1410
8.3
200
4.2

FM200 Cylinder Specification---5.6MPa 
Working Pressure: 5.6MPa Test Pressure: 8.4MPa Burst Pressure>16.90MPa 
HFC-227ea Agent Filling Rate ≤1.15
Item
Code No.
Capacity(L)
Thread
Inner Dia.(mm)
Height(mm)
Wall Thickness(mm)
Weight(kg)
Max. Working Pressure(Mpa)
1
C16/5.6-PRI
16L
PZ56/2-8UN.2A
300
408
6
22
5.6
2
C32/5.6-PRI
32L
PZ56/2-8UN.2A
300
634
6
36
5.6
3
C40/5.6-PRI
40L
PZ56/2-8UN.2A
300
747
6
37
5.6
4
C70/5.6-PRI
70L
PZ56/2-8UN.2A
350
915
6
53
5.6
5
C82.5/5.6-PRI
82.5L
PZ56/3-1/4"-8UN.2A
350
1050
6
59
5.6
6
C90/5.6-PRI
90L
PZ56/3-1/4"-8UN.2A
350
1125
6
63
5.6
7
C120/5.6-PRI
120L
M64x2/3-1/4"-8UN.2A
350
1430
6
80
5.6
8
C140/5.6-PRI
140L
M64x2/3-1/4"-8UN.2A
400
1315
7
95
5.6
9
C150/5.6-PRI
150L
M64x2/3-1/4"-8UN.2A
400
1395
7
103
5.6
10
C180/5.6-PRI
180L
M80x2/3-1/4"-8UN.2A
400
1635
8
138
5.6
11
C250/5.6-PRI
250L
M80x2/3-1/4"-8UN.2A
500
1500
9
200
5.6
12
C345/5.6-PRI
345L
M80x2/3-1/4"-8UN.2A
600
1410
10
240
5.6
FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms
FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms


Specifications for Head Valve
of FM200 Fire System (Normal Model) 
Specifications for Head Valve
of FM200 Fire System (High Level Model) 
Item
DN32
DN40
DN50
Code NO.
AV25/4.2-PRI
AV50/4.2-PRI
Code NO.
V32/4.2-PRI
V40/4.2-PRI
V50/4.2-PRI
AV25/5.3-PRI
AV50/5.3-PRI
V32/5.3-PRI
V40/5.3-PRI
V50/5.3-PRI
Item
G1"
G2"
Neck Thread
PZ56
M64xx2
M80x2
Actuator Thread
M18x1.5
M18x1.5
M18x1.5
Neck Thread
2-8UN.2A
3 1/4-8UN.2A
Dip Tube Thread
RC 1-1/4"
RC 1-1/2"
RC 2"
Actuator Thread
G1"
G2"
High pressure flexible
hose thread
M48x2
M56x2
M68x2
High pressure flexible 
hose thread
G1"
G2"
Pressure gauge thread
M10x1
M10x1
M10x1
Pressure gauge thread
1/8"NPT
1/8"NPT
Working Pressure
4.2Mpa
4.2Mpa
4.2Mpa
Working Pressure
6.7Mpa
6.7Mpa
Testing Pressure
6.3Mpa
6.3Mpa
6.3Mpa
Test Pressure
10.05Mpa
10.05Mpa
Applicable cylinder
≤100L
120L 150L
180L 250L
Applicable cylinder
<70L
70L 90L 120L 150L 180L
Installation Example
FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms
FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms
PRI-SAFETY is a one-stop FM-200 fire suppression system provider, offering end-to-end services including:
* System design & calculation (room volume, nozzle layout, pipe sizing)
* Manufacturing & factory testing of FM-200 systems and components
* International shipping & export support
* Installation guidance & technical support on site
* System commissioning & debugging
* After-sales inspection, maintenance, and technical service
From concept to long-term operation, PRI-SAFETY ensures reliable and compliant fire protection.
FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms
Packing & Delivery
FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms
FM200 Gas Total Flooding Fire System for Control Rooms and Server Rooms
Company Profile

PRI-SAFETY FIRE TECHNOLOGY is stablished in 2005, is focused on Automatic Fire Suppression Systems and Fire Equipment R&D, Design and Manufacture. 
 
The Products and Fire Systems are used in Mining Industry, Forest Industry, Agriculture, Petrochemical, Transportation, Electricity Power, Industry, Construction and other fields.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now