Water Mist Fire System Cylinder-Based Design

Product Details
Customization: Available
Retirement Life: 8 Years
Water Mist Working Pressure: 10MPa
Still deciding? Get samples of US$ 6900/Set
Request Sample

360° Virtual Tour

Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
886813.09 USD
Management System Certification
ISO9001:2015
  • Water Mist Fire System Cylinder-Based Design
  • Water Mist Fire System Cylinder-Based Design
  • Water Mist Fire System Cylinder-Based Design
  • Water Mist Fire System Cylinder-Based Design
  • Water Mist Fire System Cylinder-Based Design
  • Water Mist Fire System Cylinder-Based Design
Find Similar Products

Basic Info.

N2 Gas Bottle Working Pressure
20MPa
Nozzle Flow Rate
10L/Min, K=1.0
Nozzle Quantity
6PCS
Skid Dimension
800X3400X2080mm
Pipe and Valve Material
SUS316 High Pressure
Pressure Gauge and Solenoid Valve
Explosion-Proof
OEM
Support
Cylinder Material
Steel
Transport Package
Palletizing
Specification
70/90/100/120/150/180/250/345L
Trademark
PRI-SAFETY
Origin
China
HS Code
842410
Production Capacity
1000set/Month

Product Description

Product Description:
Water Mist Fire System Cylinder-Based Design
A water mist fire system is a fire suppression system that uses fine water sprays (i.e., mist) to control, suppress, or extinguish fires. The system is designed to use water more efficiently and effectively than traditional sprinkler systems. The fine mist is created by forcing water through special nozzles at high pressure, producing droplets that are much smaller than those in conventional sprinkler systems.

Cylinder Type Water Mist Fire Systems
In a cylinder type water mist fire system, the water (or water mixed with an additive) is stored in pressurized cylinders rather
than in a large water tank or being connected to a continuous water supply. These cylinders are typically filled with water and
pressurized with a gas, such as nitrogen.

 
Product Specifications:

Water Mist Fire System Cylinder-Based Design
Water Mist Fire System-Cylinder Type
Water Mist Working Pressure
10Mpa
Water Mist Fire Sytem Capacity
 
8x80L Water Bottles
 
8x80L N2 Gas Bottles
 
Water Bottle Working Pressure
20Mpa
 
N2 Gas Bottle Working Pressure
20Mpa
 
Nozzle Flow Rate
 
10L/min, K=1.0
 
Nozzle Quantity
6pcs
 
Pipe and Valve Material
 
800X3400X2080mm
 
Pressure Gauge and Solenoid Valve
 
Explosion-Proof
 
3D Design
Water Mist Fire System Cylinder-Based Design
Water Mist Fire System Cylinder-Based Design
Detailed Components:

A Cylinder Type Water Mist Fire System consists of several key components that work together to detect, suppress, and control fires. Here's an overview of the main components:
1. Water Cylinders
* Function: The cylinders store the water that will be used to create the mist during fire suppression.

2. Inert Gas Cylinder
* Function: The gas is used to pressurize the water cylinder, ensuring that the water is discharged at the required high pressure.

3. Distribution Piping
* Function: Distributes the water throughout the protected area to ensure effective coverage.

4. Mist Nozzles
* Function: These nozzles are crucial in creating the water mist, which effectively suppresses the fire by cooling and reducing oxygen levels around the fire.

5. Control Valves.
* Function: Regulate the release of water, ensuring it is discharged only when needed and in the correct amount.

6. Fire Detection System
* Function: Detects the presence of a fire and triggers the activation of the water mist system.
Water Mist Fire System Cylinder-Based Design

7. Control Panel
* Function: Receives signals from the fire detection system and initiates the release of water from the cylinders by opening the control valves.

8. Discharge Nozzles or Diffusers
* Function: Ensures that the water mist is evenly distributed over the area of concern to maximize fire suppression effectiveness.

9. Pressure Gauges and Monitoring Devices
* Function: Provide real-time information on system status, ensuring it is ready for operation.

10. Manual Release Stations
* Function: Allow for the manual activation of the system in case of an emergency.

11. Pipework and Fittings
* Function: Ensures the proper flow and distribution of water from the cylinders to the nozzles.

12. Discharge Warning Devices
* Function: Alerts personnel in the area to evacuate or take necessary action before the mist is released. These components work together to ensure that the Cylinder Type Water Mist Fire System is capable of quickly detecting and effectively suppressing fires with minimal water usage and potential water damage.

 
Difference between pump type water mist system and cylinder type:

The difference between pump type and cylinder type water mist fire systems primarily lies in how the water is supplied, stored, and delivered during fire suppression.

Here's a comparison of the two models:
Water Mist Fire System Cylinder-Based Design
Water Supply Source:
Cylinder Type Water Mist Fire System: Water Supply: The water is stored in pressurized cylinders, often mixed with an inert gas like nitrogen. No Pumps: Since the water is already pressurized in the cylinders, no additional pumps are needed to pressurize the water during discharge. Capacity: More limited in terms of the amount of water available since it depends on the number of cylinders. Best suited for smaller areas or localized protection.
Water Supply Source:
Pump Type Water Mist Fire System: Water Supply: This system draws water from a dedicated water tank or a continuous water supply
(e.g., a municipal water line). Pumps: High-pressure pumps are used to pressurize the water and deliver it to the mist nozzles.
Capacity: Can be designed to cover large areas since it has access to a continuous or large water source.
Water Mist Fire System Cylinder-Based Design
 

Cylinder Type Water Mist Fire System

 
System Design and Complexity

Cylinder Type Water Mist Fire System:

Simplicity: Simpler design, as it only involves the pressurized cylinders and the distribution piping to the mist nozzles. Space Requirements: More compact, requiring less space since the system doesn't need a large water tank or pump room. Scalability: Limited scalability due to the finite amount of water stored in the cylinders. To cover larger areas, more cylinders are needed.

Installation and Maintenance

Cylinder Type Water Mist Fire System:

Installation: Easier and faster to install, particularly in areas where space is at a premium or where access to a water supply is challenging. Maintenance: Maintenance mainly involves checking the pressure and integrity of the cylinders.

 
Applications

Cylinder Type Water Mist Fire System:

Commonly used in smaller, specialized environments like engine rooms, data centers, heritage buildings, and locations where water damage needs to be minimized and space is limited.

 
Response Time

Cylinder Type Water Mist Fire System:

Generally offers faster response times since the water is already pressurized and ready to be discharged instantly upon activation.

 
Summary
Cylinder Type:
Best for smaller, compact, or specialized applications where space is limited, and rapid response is crucial.

Pump Type Water Mist Fire System

System Design and Complexity

Pump Type Water Mist Fire System:

Complexity: Generally more complex in terms of installation and maintenance due to the need for high-pressure pumps, water supply lines, and a potentially larger network of pipes. Space Requirements: Requires space for a water storage tank, pumps, and associated equipment. Scalability: Easily scalable to cover larger areas by adding more pumps or increasing water storage.

Installation and Maintenance

Pump Type Water Mist Fire System:

Installation: Generally requires more extensive installation work, including water supply infrastructure and pump setup. Maintenance: Requires regular maintenance of pumps, valves, and the water supply system.

Applications

Pump Type Water Mist Fire System:

Typically used in larger facilities such as industrial plants, commercial buildings, and facilities where a reliable and continuous water supply is available

Response Time

Pump Type Water Mist Fire System:

Activation may involve a slight delay as pumps need to start and build up pressure, though this is typically very quick.

Summary
Pump Type:
Suitable for larger applications, continuous water supply, and scalability.
Water Mist Fire System Cylinder-Based Design
Water Mist Fire System Cylinder-Based Design
 
More Views:
Water Mist Fire System Cylinder-Based Design
FAQ

1. who are we?
We are based in Zhejiang, China, start from 2009,sell to South America(25.00%),North America(15.00%),Southeast Asia(15.00%),Mid East(12.00%),Africa(7.00%),Eastern Europe(5.00%),South Asia(3.00%),Eastern Asia(3.00%),Oceania(3.00%),Western Europe(3.00%),Southern Europe(3.00%),Central America(3.00%),Northern Europe(2.00%),Domestic Market(1.00%). There are total about 11-50 people in our office.

2. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;

3.what can you buy from us?
FM200 Fire Systems; Vehicle Automatic Fire Systems; Kitchen Automatic Fire Systems; CAFS Fire Systems; Automatic Fire Tube

4. why should you buy from us not from other suppliers?
One Stop Fire Fighting Equipment supply and professional service. We have CE, EN3, EN671, EN1869 certificates. Mainly export to Europe, Middle east, South America, Africa,etc.

5. what services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF,EXW,Express Delivery;
Accepted Payment Currency:USD,CNY;
Accepted Payment Type: T/T,L/C,D/P D/A,Western Union,Cash;
Language Spoken:English,Chinese,Spanish

Water Mist Fire System Cylinder-Based Design

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier