ATM Automatic Fire Safety Systems
1. ATM Automatic Fire Safety Systems Product Description.
For a long time, the ATM machines were often stolen. Brought huge losses to the bank. The security problem of the ATM machines has become more and more serious, which has aroused the attention of senior bankers. Our company has developed a new product that can solve this problem well. It can greatly reduce ATM theft. Protect property safety.
The ATM machine automatic safe system consists of a FM200 cylinder, Ink cylinder, gas detector, solenoid valve with a control panel and alarm system. The one cylinder is filled with FM200 agent and the other cylinder is Ink agent.
2. How ATM Automatic Fire Safety Systems works?
tAccording to the investigation, the thief's method of committing crimes is usually to slowly inject gasoline into the ATM machine, explode the ATM machine, and take the cash away from the ATM machine.
Our product is when gasoline is injected into the ATM machine, the gasoline is detected immediately, the alarm system is turned on, and the special ink is sprayed on all the cash, damage the cash. Colleagues equipped with FM200 fire extinguishers began to work to dilute gas oxygen to explosion prevent the ATM explosion.
There is another simple protection method, which can make the money stolen by the thief unusable, thereby indirectly protecting the property.
When the heat detector and the vibration detector detect the temperature and the corresponding vibration frequency, then they will send the signal to the control panel, and then the control panel will send the signal to the solenoid valve, then the solenoid valve will automatically activate, and then it will start to discharge the special ink is applied to the cash, so that the cash cannot be used in circulation, thereby indirectly protecting property.
CAPACITY of ATM Automatic Fire Safety Systems
|
4kg Ink 1kg FM200 |
Cylinder THREAD of ATM Automatic Fire Safety Systems
|
M30*1.5 |
MATERIAL of ATM Automatic Fire Safety Systems
|
St13/DC01 |
WORKING TEMPERATURE of ATM Automatic Fire Safety Systems
|
0~+60ºC |
WORKING PRESSURE of ATM Automatic Fire Safety Systems
|
14Bar |
TEST PRESSURE of ATM Automatic Fire Safety Systems
|
27Bar |
ACTIVATION METHOD of ATM Automatic Fire Safety Systems
|
Automatically by gas detector. |