Dry Powder Automatic Fire Protection Systems for Heavy Machines

Product Details
Customization: Available
Type: Portable Fire Extinguisher
Certification: CE

360° Virtual Tour

Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
886813.09 USD
Management System Certification
ISO9001:2015
  • Dry Powder Automatic Fire Protection Systems for Heavy Machines
  • Dry Powder Automatic Fire Protection Systems for Heavy Machines
  • Dry Powder Automatic Fire Protection Systems for Heavy Machines
  • Dry Powder Automatic Fire Protection Systems for Heavy Machines
  • Dry Powder Automatic Fire Protection Systems for Heavy Machines
  • Dry Powder Automatic Fire Protection Systems for Heavy Machines
Find Similar Products

Basic Info.

Model NO.
AFFS-06 AFFS-09 AFFS-12 AFFS-18
Portable Extinguisher
Portable Foam Fire Extinguisher
Effective Range
4m
Retirement Life
8 Years
Power Source
Pressure Fire Extinguisher
Activation
Temperature Reach to Start Degree
Capacity
2L, 6L, 9L, 12L,18L Support OEM.
Working Pressure
15bar
Testing Pressure
27bar
Application Scope
Mining Machine
Cylinder Material
SS304 or St12
Filled or Empty
Both Can Do.
Brand
Pri-Safety
Transport Package
Carton Box
Specification
2L, 6L, 9L, 12L AFFF3% Foam/FM200. Support OEM.
Trademark
PRI-SAFETY
Origin
China
HS Code
84241000
Production Capacity
10000/Month

Product Description

Dry Powder Automatic Fire Suppression System for Heavy Equipments
 
1. Product Background.
Engine compartments of buses are more tendency to catch fire than other enclosures due to the following: short circuit, engine wear, hot surfaces, reduced durability of materials, use of plastics, encapsulation of the engine, oil, and debris. It is not surprising that more than 70% of all bus fires occur in the engine compartment. Since buses are used for every day transport of people, the fire protection of buses should be top priority of every bus operator or manufacturer.

We have two different ways to activate the system.
1. Temperature Sensor Model/Solenoid Valve.
2. Detection Tube Model/Pneumatic Valve.


2. Specification
 

PRI-SAFETY Mining Machine Fire Suppression Systems

Brand Name

PRI-SAFETY

Capacity

6L, 9L, 12L, 18L, 20L, 25L, 50L-FOAM (18L for 4CBM Engine Room)

6kg, 9kg, 12kg, 18kg, 25kg, 50kg---Dry Powder (9kg for 4CBM Engine Room)

Agent

Foam / Dry Powder 

Working Pressure

14Bar

Testing Pressure

27Bar

Cylinder Material

St12 red painting Or Stainless Steel 304

Certificate

UN ECE R107 , CE 

System Activated Temperature

140ºC or Customized Temperature

 
Note: For Vehicle Engine Room, we can choose different fire agents, such as  Water, AFFF3% Foam, FM200, or Dry Powder agents. The different systems are with different discharge tube and nozzles.

3. Product Advantage
  • Totally automatic system
  • Independent of power supply
  • Fast detection and high efficiency
  • Available in many agents: foam, novec1230, water mist, dry powder, FM200,ect
  • Adapted to harsh environments
  • Universal to be installed in any bus
  • Cost-effective Eco-Friendly
  • Rechargeable
  • Less damage to buses
  • Reduction of societal costs
  • Secure business continuity
4. Product Activated Principle.
1). Temperature Sensor Model/Solenoid Valve

Dry Powder Automatic Fire Protection Systems for Heavy Machines
Step1: There is 3 temperature sensor installed in the engine room, temperature sensor feedback the the temperature to the control panel. The control panel can indicate the temperature at anytime. The control panel was installed in the driver room, driver can see the temperature at anytime.
Step2: Once the Temperature of engine room increase to 100ºC, the control panel will activate the fire alarm. Driver will stop and check the situation. If necessary, driver will push the manual button on the control panel to activate the system.
Step3: Once the temperature still increasing, and reach to 140ºC, the temperature sensor feedback the signal to control panel, the control panel will activate the solenoid Valve, the solenoid Valve open and discharge agent to extinguish fire.

The temperature sensor send temperature signal to control panel, the control panel can indicate the temperature at anytime, once temperature reach 100 ºC, the fire alarm was activated. Once the temperature reach 140ºC, control panel will send signal to electric valve to open it. Then the agent was discharged from dischange tube and nozzles. On the control panel, there is a manual button and test button, reset button, in Emergency pushing  the manual button can activate the fire system too.

Application Example
Dry Powder Automatic Fire Protection Systems for Heavy MachinesDry Powder Automatic Fire Protection Systems for Heavy Machines
2). Detection Tube Model/Pneumatic Valve
Dry Powder Automatic Fire Protection Systems for Heavy Machines
Step1: Detection Tube ruptures to hole when temperature reach 140ºC, and release pressure through the hole.(Or pushing the manual button of detection tube,pressure releasing from themanual button.)
Step2: The resulting drop in pressure causes the head valve to be activated. At the same time the fire arlar was activated. Valve was opened and agent was discharged through the discharge tubing to the nozzles.
Step3: Agent covering the area and suppressing the fire quickly and thoroughly. This system is totally automatic and is totally independent of electricity.

Inside the Pneumatic valve there is a piston, it divide the valve cavity to 2 parts. The upper cavity connect to detection tube, the lower cavity connect to bottle. The pressure of the 2 side of the piston is same. During the fire, Once the detection tube detected fire and ruptured one hole to release the pressure. Then the pressure of 2 side of the piston happen different, the piston was moved to up, and the outlet port of the valve was opened, and agent was discharged from the pipe and nozzles. At the same time, the pressure switch send final to fire alarm, the fire alarm was activated.  On the control panel, there is a manual button and test button, reset button. In emergency Pushing the manual button can activate the fire system too.

Application Example
Dry Powder Automatic Fire Protection Systems for Heavy MachinesDry Powder Automatic Fire Protection Systems for Heavy Machines
5. Product Certificate
CE, ECE R107, and ISO certificate for automatic fire suppression system.
Dry Powder Automatic Fire Protection Systems for Heavy Machines
6. Application for Veichle
Engine Compartments of All On-Road Vehicles and Off-Road Vehicles: Car, Van, Bus, Mini Bus, Truck, Rally Car, Mining Machine or Construction Machine, etc.
Dry Powder Automatic Fire Protection Systems for Heavy Machines
Dry Powder Automatic Fire Protection Systems for Heavy Machines
Dry Powder Automatic Fire Protection Systems for Heavy Machines
7. Packing and Shipping
Period of shipping, normally within 15 working days upon receipt of deposit.
Dry Powder Automatic Fire Protection Systems for Heavy Machines
More details kindly contact us at any time.
Dry Powder Automatic Fire Protection Systems for Heavy Machines
Thanks for your supporting and trusting...

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier