• Fire Trace Valve for CO2 Fire Suppression System
  • Fire Trace Valve for CO2 Fire Suppression System
  • Fire Trace Valve for CO2 Fire Suppression System
  • Fire Trace Valve for CO2 Fire Suppression System
  • Fire Trace Valve for CO2 Fire Suppression System
  • Fire Trace Valve for CO2 Fire Suppression System

Fire Trace Valve for CO2 Fire Suppression System

Agent: CO2
Type: Automatic
Object: CO2 Fire System
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Fire Trace Valve for CO2 Fire Suppression System pictures & photos
Fire Trace Valve for CO2 Fire Suppression System
US $33 / Set
Min. Order: 500 Sets
Diamond Member Since 2006

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
DCV-01 DCV-02 DCV-03
Size
DCP-01 DCP-02 DCP-03
Certification
CE
Portable Extinguisher
Automatic
Effective Range
4.5m
Retirement Life
5 Years
Dry Powder Type
Superfine Powder
Power Source
Pressure Fire Extinguisher
Fire Agent
CO2
Application
CO2 Fire System
Model
Dcv-01 Dcv-02 Dcv-03
Product Name
Fire Trace Valve for CO2 Fire Suppression System
Key Words
Fire Trace Valve for CO2 Fire Suppression System
Raw Material of Cylinder
Brass
Transport Package
Professional Export Carton
Specification
450x290x200mm
Trademark
PRI-SAFETY
Origin
Hangzhou, China
HS Code
8481804090
Production Capacity
100000 Units/Year

Product Description

Fire Trace Valve for CO2 Fire Suppression System
Fire Trace Valve for CO2 Fire Suppression System
Fire Trace Valve for CO2 Fire Suppression System
Fire Trace Valve for CO2 Fire Suppression System

 
Introduction:
Designed to protect electrical enclosures&circuitry, PRI-SAFETY's comprehensive, pre-engineered Electrical Cabinet Fire Suppression System reduces the risk of electrical fires, and prevents potential devastation to business and property. it protects business assets/facilityy. Perfect for place where fire hazards are likely to be in the enclosed space, it leaves out no residue behind which eliminates the need for an extensive area clean up.

Minimises electrical fire risks including short circuits, overloading, overheating, electrical surges, etc.
Full automatic operation;
Can be installed directly inside electrical cabinets, closer to where fires usually start;
Optional dual-valve outlet: reliable, affordable protection even for large-sized cabinets;
Leaves no dirty residue or unpleasant odour;
Environment-friendly operation;

Note:
Due to the health risks posed by high levels of CO2 discharged from the suppression system, a number of life safety devices and mechanisms are put in place in and around the protected spaces. One such device is a pneumatic siren that is used to alert personnel when CO2 will be discharged from the system. In addition to these safety mechanisms, it is critical to train all employees and personnel in the building on the health risks of a CO2 fire suppression system, as well as appropriate evacuation procedures in the event of a fire.


Specification:
Product Name
Fire Trace Valve for CO2 Fire Suppression System
Model
DCV-01 DCV-02 DCV-03
Material Brass
Pressure Gauge thread M10X1-12.5
Ball Valve thread
1/8''NPT
Application
Co2 Fire System
Application
Fire Trace Valve for CO2 Fire Suppression System
Fire Trace Valve for CO2 Fire Suppression System
Fire Trace Valve for CO2 Fire Suppression System
Product Usage of Fire Trace Valve for CO2 Fire Suppression System
Application Small Electrical Control Cabinet, Large Electrical Control Cabinet, Electrical Switch Panels, Electronic Devices, Server Room, can protect any electrical cabinet;
Fire Trace Valve for CO2 Fire Suppression System
Fire Trace Valve for CO2 Fire Suppression System
Fire Trace Valve for CO2 Fire Suppression System
Working Principle of Fire Trace Valve for CO2 Fire Suppression System: 
Direct type: When there is a fire, and reach 140 degrees celsius, the tube will repture a hole, and the fire agent will discharge from this hole to extinguish fires within several seconds.
Indirect type: When there is a fire, and reach 140 degrees celsius, the tube will repture a hole, then the pressure will release from the hole, and it will leads to activate the valve of the fire system to open, then the fire agent will discharge from discharge pipe to extinguish fires within several seconds.
 
Packing&Shipping of Fire Trace Valve for CO2 Fire Suppression SystemFire Trace Valve for CO2 Fire Suppression System will be packed export carton, and also can be packed by wooden pallet after packing by export carton if necessary.
Fire Trace Valve for CO2 Fire Suppression System
Fire Trace Valve for CO2 Fire Suppression System
Company Introduction Of Fire Trace Valve
Hangzhou PRI-SAFETY Fire Technology Co.,Ltd. are the professional manufacturer of automatic fire suppression system and fire extinguishers for many years. And our main product: automatic fire suppression system(for kitchen, for electrical device, for vehicle), CAFS Compressed Air Foam System, Fire Extinguishers, Stainless Steel Fire Extinguishers, and other fire fighting equipment.
Fire Trace Valve for CO2 Fire Suppression System
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now