Automatic Fire Suppression Tube for Battery Packs
Description:
PRI-SAFETY automatic fire suppression tube, also known as an automatic fire suppression system or fire suppression tube, is a type of fire protection device that is designed to detect and suppress fires in various environments.
It is commonly used in areas where traditional fire suppression systems, such as sprinkler systems, may not be practical or effective. Here it is designed to apply to the battery packs.
Characteristic:
1. Automatic:
The automatic fire suppression tube operates automatically without the need for human intervention or manual activation.
2. Fire suppression:
The primary purpose of the tube is to suppress or extinguish fires.
3. Shape:
Refers to the flexible cylindrical structure that contains the fire-suppressing agent and ruptures when exposed to heat.
4. Fire protection:
The tube provides protection against fire hazards by detecting and suppressing fires.
5. Heat-sensitive:
The material of the tube is sensitive to heat and ruptures when it reaches a certain temperature threshold.
6. Localized protection:
The tube is capable of providing fire suppression in a specific area or directly at the source of the fire.
7. Non-water-based:
The tube may use clean gas as the fire-suppressing agent, rather than relying on water-based systems like sprinklers.
8. Rapid response:
The system reacts quickly to fire incidents, minimizing the spread of flames and reducing potential damage.
Code |
TFS-0.5 |
TFS-01 |
TFS-02 |
TFS-03 |
TFS-04 |
TFS-05 |
TFS-06 |
Length x Dia |
0.5mx18mm |
1mx18mm |
2mx18mm |
3mx18mm |
4mx18mm |
5mx18mm |
6mx18mm |
Agent Capacity |
100g |
200g |
400g |
600g |
800g |
1000g |
1200g |
Protection Space |
0.1 ~0.125m3 |
0.2~0.25m3 |
0.4~0.5m3 |
0.60~0.75m3 |
0.80~1.00m3 |
1.0~1.25m3 |
1.20~1.50m3 |
Agent Type |
FM-200(HFC-227ea) |
Material |
Polyamide Tube
|
Pressure at 20° C |
0~4 Bar |
Pressure at 100° C |
15bar |
Burst Temperature |
120° C± 10 ° C |
Working Temperature |
-40° C~+90° C |
Shelf Life of Systems |
5 years |
Maintenance:
1. Regularly observe whether the pressure gauge is in the green range and whether there is leakage in the tube.
2. Regularly check whether the tube is fixed in good condition.
3. Check whether the pipe is damaged by external force.
4. Make sure that the pipe is in good working condition.
5. The tube cannot be forcefully folded. Don't cut.
Production Line:
FAQ.
1)Where can you use this Automatic Fire Extinguisher Tube for Battery Packs?
Electrical panels, engine compartments, battery packs, eletrical panels and etc.
2).Are your company PRI-SAFETY manufacturer or trading company?
---We are a professional Manufacturer of automatic fire suppression systems and fire extinguishers. We have our own factory to produce the fire fighting equipments.
3).Can you print our logo on products?
---Yes, no problem.We also support OEM.
4).How long does it take to delivery?
--- As usual, it will take about In 30-45 working days.
7).What's your MOQ?
---The MOQ is 500pcs.
Our automatic fire suppression tube belongs to general goods, it could be shipped via LCL and courier.
If you have quantity demand, we could provide you the sample via FedEx once you confirm the order.