Data Room Clean Gas Hfc-227ea Total Flooding Fire System

Product Details
Customization: Available
Power: DC24V/1.6A
Min Working Pressure: 4.2MPa
Still deciding? Get samples of US$ 4000/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
886813.09 USD
Management System Certification
ISO9001:2015
  • Data Room Clean Gas Hfc-227ea Total Flooding Fire System
  • Data Room Clean Gas Hfc-227ea Total Flooding Fire System
  • Data Room Clean Gas Hfc-227ea Total Flooding Fire System
  • Data Room Clean Gas Hfc-227ea Total Flooding Fire System
  • Data Room Clean Gas Hfc-227ea Total Flooding Fire System
  • Data Room Clean Gas Hfc-227ea Total Flooding Fire System
Find Similar Products
  • Overview
  • Product Description
  • Working Principle
  • Product Programs
  • Product Details
  • Applications
  • Work shop
  • Exhibitions
  • About Us
Overview

Basic Info.

Filling Pressure
4.2MPa
Max Working Pressure
5.3MPa
Capacity
90L, 120L, 150L, 180L
Brand
Pri-Safety
Working Temp.
0~+50degree
Transport Package
by High Quality Export Packaging
Specification
90L, 120L, 150L, 180L
Trademark
PRI-SAFETY
Origin
China
HS Code
842410
Production Capacity
1000sets/Month

Product Description

Automatic FM200 Total Flooding Fire Suppression System

Product Description

Data Room Clean Gas Hfc-227ea Total Flooding Fire System

FM-200 is an odorless, colorless, liquefied compressed gas. It is stored as a liquid and dispensed into the hazard as a colorless, electrically non-conductive vapor that is clear and does not obscure vision. It leaves no residue and has acceptable toxicity for use in occupied spaces at design concentration. FM-200 extinguishes a fire by a combination of chemical and physical mechanisms.FM-200 provides excellent fire protection in a wide range of applications from sensitive electrical equipment to industrial applications using flammable liquids. FM-200 agent is used in total flooding fire suppression systems.
FM-200 does not work by displacing oxygen and is safe for use in occupied spaces without fear of oxygen deprivation

Working Principle

When the control mode selection key on the automatic fire alarm and fire extinguishing controller is set to the "auto" position, the fire extinguishing system is under automatic control. When a fire occurs in the protection area, the temperature and smoke detectors will send out a fire signal through the automatic fire alarm and extinguishing control After the logic analysis of the device, it sends out a combined sound and light alarm signal, and sends out a linkage command at the same time to close the linkage device. After a delay, a fire extinguishing command is issued, the starting valve is opened to release the starting gas, and the starting gas is opened through the control gas pipeline valves and container valves release the fire extinguishing agent and implement fire extinguishing.
Data Room Clean Gas Hfc-227ea Total Flooding Fire SystemAdvantages:
Data Room Clean Gas Hfc-227ea Total Flooding Fire System

Product Programs

 

Data Room Clean Gas Hfc-227ea Total Flooding Fire SystemData Room Clean Gas Hfc-227ea Total Flooding Fire SystemData Room Clean Gas Hfc-227ea Total Flooding Fire System

Product Details

 

Data Room Clean Gas Hfc-227ea Total Flooding Fire System

1. Storage cylinder: Cylinder, container valve (with pilot valve, pressure indicator), dip tube, etc. 2. Liquid check valve: Assure one way flow of fire suppression agent, to prevent backflow.
3. High pressure hose: Connect cylinder valve and liquid check valve .
4. Safety valve: Fitted on the manifold to relieve higher pressure.
5. Selection valve: Guide fire suppression agent into different distribution pipe network.
6. Starting gas bottle: Bottle, container valve, electromagnetic drive device, pressure gauge.
7. Gas check valve: Assure one way flow of starting gas, to prevent backflow.
8. Low leakage high sealing valve: For accumulated starting gas release so to avoid malfunction of system.
9. Discharge Nozzle: Fitted at the end of pipe network to discharge fire suppressing agent. 10. Control System: Control panel, smoke and heat detector, fire alarm, discharge indicator light, etc.
Data Room Clean Gas Hfc-227ea Total Flooding Fire System
 
Data Room Clean Gas Hfc-227ea Total Flooding Fire SystemData Room Clean Gas Hfc-227ea Total Flooding Fire SystemData Room Clean Gas Hfc-227ea Total Flooding Fire SystemData Room Clean Gas Hfc-227ea Total Flooding Fire SystemData Room Clean Gas Hfc-227ea Total Flooding Fire SystemData Room Clean Gas Hfc-227ea Total Flooding Fire SystemData Room Clean Gas Hfc-227ea Total Flooding Fire SystemControl Panel Components:
The control panel for an FM200 total flooding system is a critical component that monitors, controls,
and coordinates the various elements of the fire suppression system.

The components are as followings:
Data Room Clean Gas Hfc-227ea Total Flooding Fire System

Agent:
Clean agent extinguishing systems fight fires using the chemical extinguishant Novec 1230  or with the chemical extinguishant HFC-227ea. This extinguishant is neither corrosive nor electrically conductive. It is thus especially suitable for protecting rooms containing electric and electronic equipment. The systems extinguish fires without leaving residue, while offering a high level of personal and environmental protection at the same time. They are particularly suitable for the protection of small and medium-sized rooms, and the extinguishing agent can be stored compactly, either inside the room or in another area.
Data Room Clean Gas Hfc-227ea Total Flooding Fire System

Applications

Data Centers and Server Rooms:
Data centers house critical and sensitive electronic equipment, including servers and networking infrastructure. The FM200 system is well-suited for these environments as it provides rapid fire suppression without causing damage to the electronic components.

Telecommunication Facilities:
Facilities with communication equipment, such as telecommunication rooms and facilities housing switching equipment, benefit from the use of FM200 systems. The clean agent extinguishes fires without leaving residue that could harm sensitive telecommunications equipment.

Control Rooms:
Control rooms in various industries, such as manufacturing, energy, and transportation, often contain valuable and critical control systems. The FM200 system can protect these spaces without causing damage to control panels, displays, and other equipment.


Laboratories:
Research laboratories may house valuable and sensitive equipment, chemicals, and experiments. The FM200 system is suitable for protecting these environments without causing collateral damage to the equipment or experiments.

Museums and Archives:
Cultural institutions, museums, and archives may use FM200 systems to protect valuable artifacts, documents, and collections. The clean agent leaves no residue, reducing the risk of damage to delicate items.

Medical Facilities:
Certain medical facilities, such as imaging rooms and facilities with sensitive medical equipment, can benefit from FM200 fire protection. The system is non-corrosive and safe for use in environments with medical equipment.

 

Work shop

Data Room Clean Gas Hfc-227ea Total Flooding Fire System

Exhibitions

Data Room Clean Gas Hfc-227ea Total Flooding Fire System
Data Room Clean Gas Hfc-227ea Total Flooding Fire System

 

Data Room Clean Gas Hfc-227ea Total Flooding Fire System
Data Room Clean Gas Hfc-227ea Total Flooding Fire System

About Us

PRI-SAFETY was established in 2004, is professional manufacturer of FM200 HFC227EA Fire Suppression System,
Automatic Fire Suppression System (For Kitchen. For Vehicle, For Electrical Devices),
CO2 Total Flooding Fire System,
Tube Automatic Fire Suppression System / Automatic Tube Fire Extinguisher,
CAFS Fire Systems (Compressed Air Foam Fire System),
Stainless Steel Fire Extinguisher,
Throwing Fire Extinguisher,
Cooking Oil Fire Extinguisher,Fire Extinguisher,etc.
Our products are mainly export to Europe, Middle east, America, South America, Africa, etc. Most of our products are with approval of CE, UN ECE R107, China CCC, UL, etc. We produce high quality fire fighting products, and we supply one-stop purchasing service too.

Data Room Clean Gas Hfc-227ea Total Flooding Fire System
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier